Abstract
When the endotracheal tube is removed, blood pressure elevates and heart rate increases. In order to evaluate the hemodynamic changes after removal of a new developed device-laryngeal mask airway, we measured the change of the systolic & diastolic blood pressure and heart rate of 120 patients undergoing general anesthesia. The results were elevation of blood pressure and heart rate after extubation or removal on both groups immediately. But the degree of changes were 18.7+/-1.6% in the endotracheal tube groups and 12.3+/-1.4% in the laryngeal mask airway groups in systolic blood pressure respectively. Therefore the degree of changes of the laryngeal mask airway groups was significantly small (p<0.05). The comparison of the change of diastolic blood pressure was not significant. The degree of the change in heart rate was 19.6+/-2.8% in the endotracheal tube groups and 9.2+/-2.2% in the laryngeal mask airway groups. Therefore the degree of the ehange in blood pressure and heart rate of the laryngeal mask airway groups was significantly small (p<0.05).
Key Words: Extubation; Laryngeal mask airway; Endotracheal tube


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next