Introduction
With the recent developments in surgical maneuvers and the increase in demand for noninvasive treatments, there have been an growing number of procedures that involve changes in body positioning and laparatomy. Patients under general anesthesia who undergo the above may experience biological changes due to the effects of these positional changes on the cardiovascular and respiratory system. Therefore, patients who undergo changes in body positioning require monitoring of the cardiovascular and respiratory systems. In controlled ventilation using modern anesthetic monitoring devices, the peak inspiratory pressure (PIP) and plateau pressure (P
plat) can be measured by a monitor, and the respiratory dynamics can be monitored and evaluated indirectly. When the amount of gas that expands the lungs is constant, the increase in PIP is considered to be the state when the airway resistance (R
aw) increases, when pulmonary compliance decreases, or when both occur simultaneously [
1].
In general anesthesia using muscle relaxants, moving the patient from the supine to prone position while using a mechanical ventilator for controlled ventilation affects the patient's respiratory dynamics and vital signs. Owing to the pressure on the abdomen, the internal organs push the diaphragm towards the direction of the head. In addition, the weight of the trunk decreases the diameter of the chest. With such movement limitations, the respiratory compliance decreases by 20-30% and the PIP increases. Therefore, the increase in PIP in the prone position has been attributed to the decrease in respiratory compliance [
2-
4].
On the other hand, some studies employed surgical tables with abdomen rolls to allow for the free movement of the abdomen. Therefore, the prone position rather than the supine position has been reported to improve the respiratory dynamic changes. Pelosi et al. [
5] reported that the prone position during general anesthesia improves the lung volume and oxygenation without significantly altering the respiratory, pulmonary, or chest wall compliance. In addition, Palmon et al. [
6] stated that the prone position using a Jackson surgical table does not significantly change the PIP or pulmonary compliance in patients with a normal weight. The use of a Jackson surgical table rather than a Wilson surgical table or a chest roll causes the least change in PIP and pulmonary compliance in patients with both normal and abnormal weights.
In this study, the increase in PIP was monitored using a patient monitoring device when changes in body positioning to the prone position were made using a Jackson surgical table. The authors also made the assumption that the change in PIP affects the pulmonary compliance and Raw. Patients scheduled to undergo spinal surgery using a Jackson surgical table were moved from the supine to the prone position to observe the effects of the PIP and Pplat on the dynamic compliance (Cdyn) and Raw using a respiratory dynamics monitoring device.
Materials and Methods
After gaining the approval of the ethics committee, the study was performed on 25 American Society of Anesthesiologists' physical status class I & II male and female adult patients, aged 20-65 years, who were scheduled to undergo surgery under general anesthesia for lumbar disc herniation or spinal stenosis. They agreed to participate after having being explained the study and after they had asked questions. Patients were excluded if they had a history of abnormalities in the cardiovascular system or respiratory system, or if they had spinal disorders that had caused changes to the respiratory system, such as scoliosis, lordosis, kyphosis and ankylosing spondylitis. There were 25 patients with a mean age and body mass index of 44.1 ± 13.2 years and 24.8 ± 3.1 kg/m
2, respectively (
Table 1).
All patients were fasted from midnight before surgery. On the day of surgery, midazolam 2 mg and glycopyrrolate 0.2 mg were administered IM, and famotidine 20 mg was administered IV 30 minutes before arriving into the OR. On the operating table a patient monitoring device (24c Omnicare®, Hewlett Packard, Houston, TX, USA) was used for continuous monitoring of the electrocardiography, heart rate and oxygen saturation. In all patients, proper mask ventilation was confirmed if the patient lost consciousness after the IV administration of propofol when anesthesia was induced. Rocuronium 0.8 mg/kg was administered IV for adequate muscle relaxation. Muscle relaxation was confirmed 2 minutes after administering rocuronium IV. Intubation was then performed using a wire-reinforced tube, 8.0 mm in diameter for males and 7.5 mm in diameter for females. After confirming by auscultation that the breath sounds of both lungs were the same, the intubation tube was fixed at the depth of 23-24 cm for males and 21-22 cm for females. Before starting the procedure, anesthesia was maintained by O
2 2 L/min, N
2O 2 L/min, and sevoflurane 1.5 vol%. Mechanical ventilation was set at a constant pace of a tidal volume 10 ml/kg and a respiration rate of 10 bpm. In the radial artery, a 20 gauge arterial catheter was placed to allow continuous measurements of the arterial blood pressure and for arterial blood sampling. After the required 10 minutes after endotracheal intubation to allow the vital signs to stabilize and for the changes in pulmonary compliance and pulmonary resistance to return to the state before airway irritation [
7], a respiratory dynamics monitoring device (Ventcheck®, Novametrix Medical System, Wallingford, CT, USA) was connected to the end of the endotracheal tube to measure the PIP, P
plat, R
aw, and C
dyn. All values were measured 3 times, and the median value was used for further analysis. The arterial PaO
2 and PaCO
2 were measured by arterial analysis, and the blood pressure and heart rate were monitored. All patients used a Jackson surgical table for the prone position. This was done using the method proposed by Smith [
8], which involved supporting the upper chest and abdomen by a roll and allowing for free movement of the abdomen. The head was kept in the neutral position by placing it on a horse-shoe shaped head rest. After confirming that the fixed position of the tubes of the patient in the prone position did not change, the breath sounds of both lungs were confirmed by auscultation to be the same. After the patient was stabilized for 10 minutes, the respiratory dynamics were measured using the same methods as in the supine position and compared. All measurements are reported as the mean ± SD. Data analysis was performed by SPSS (version 12.0, SPSS inc., Chicago, IL, USA) using a paired t-test. A P value < 0.05 was considered significant.
Results
When changing the body positioning of the patient from the supine position to the prone position, the mean arterial PaO
2 increased from 251.7 ± 15.1 mmHg to 283.6 ± 10.7 mmHg. The mean PaCO
2 decreased from 37.1 ± 1.0 mmHg to 35.5 ± 1.0 mmHg. However, the differences in both parameters were not statistically significant. There were no significant changes in the systolic and diastolic blood pressure or the heart rate (
Table 2).
The PIP significantly increased (15.3 ± 2.8 mmHg vs. 16.7 ± 2.7 mmHg, P < 0.05) but there were no significant changes in the P
plat (10.8 ± 2.3 mmHg vs. 11 ± 2.5 mmHg, P > 0.05). In addition, the difference between the PIP and P
plat increased significantly (4.6 ± 0.9 mmHg vs. 5.7 ± 1.7 mmHg, P < 0.05,
Fig. 1).
R
aw increased significantly when the body positioning was changed in a similar manner as the difference between the PIP and P
plat increased significantly (22.7 ± 9.8 cmH
2O/ml/s vs. 25.3 ± 11.6 cmH
2O/ml/s, P < 0.05). However, C
dyn significantly decreased (68.2 ± 18.8 ml/cmH
2O vs. 56.2 ± 16.5 ml/cmH
2O, P < 0.05,
Fig. 2).
Discussion
These results revealed an increase in PIP but not in the P
plat. The P
plat was measured at the state when the gas flow was blocked. The difference between the PIP and P
plat is the pressure needed to overcome R
aw. Therefore a constant P
plat with an increase in PIP indicates an increase in R
aw [
9]. These results revealed a decrease in C
dyn. C
dyn is affected by the inspiratory gas flow, R
aw and the equilibrium between the proximal tip and distal end of the airway [
10]. A decrease in C
dyn occurs in cases of an increase in R
aw or a decrease in pulmonary and thoracic elasticity [
11]. Therefore, the increase in PIP was attributed to the increase in R
aw or decrease in C
dyn.
According to previous studies on the prone position, abdominal movement is limited when the abdomen is pressed and the internal organs push the diaphragm in the direction of the head [
2-
4]. Moreover, the weight of the trunk reduces the diameter of the chest wall and limits movement, which reduces the respiratory compliance by 20-30%. Therefore, the increase in PIP is believed to be due to a decrease in pulmonary compliance. In contrast, if the patient is positioned where the upper chest and pelvis are supported allowing for the free movement of the abdomen, as Smith [
8] suggested, it would produce less restriction of the chest wall than other body positioning apparatuses. Moreover, Cho et al. [
12] stated that there are no significant changes in respiratory or pulmonary compliance as the patient's position was changed from the supine to the prone position. This is because compared to other body positioning apparatuses, the Jackson table does not press the upper abdomen but allows free movement of the abdomen, and has the least effect on the respiratory system. In this study, the patients were moved to the prone position using a Jackson table, so the cause for the increase in PIP does not appear to be due to the effects of a decrease in pulmonary compliance but from an increase in R
aw.
A variety of reasons can lead to an increase in R
aw. The increase in R
aw may be due to a problem with the endotracheal tube, such as kinking of the tube or overexpansion of the air-cuff, or it may be due to an obstruction of the airway by secretions, blood and other objects [
13]. The increase in R
aw after placing the patient in the prone position was attributed primarily to airway secretion. In such cases, the cause for the increase in R
aw is likely to be an endotracheal tube obstruction, airway obstruction due to mucus, or bronchospasm, which can be improved if the secretion is removed. There are reported cases where patients in the prone position repeatedly had obstructed endotracheal tubes due to a secretion in the lung or blood drainage due to the force of gravity [
14-
16]. Baydur et al. [
17] also stated that the increase in respiratory and pulmonary resistance occurs from the accumulation of airway secretion with time. This study is limited in that it made observations after only a short period of 10 minutes after the changing the body position. To confirm the cause, measurements of the R
aw should be carried out after a longer time has passed since taking up the prone position.
The other cause can be considered to be a decrease in the chest wall elasticity. Pelosi et al. [
5] stated that moving the patient into the prone position compared to the supine position increases the respiratory resistance by 20%. This 20% increase in respiratory resistance is believed to be due to a decrease in thoracic elasticity because the tidal volume is maintained at a constant rate. In addition, Cho et al. [
12] explained that the increase in chest wall compliance occurs when the apparatus used to support the upper chest in the body positioning changes presses the upper chest, which can explain the increase in R
aw.
Considering the increase in R
aw due to kinking of the endotracheal tube, most procedures with the patient in the prone position use a wire-reinforced tube to minimize kinking. Kil and Bishop [
18] reported that kinking of the endotracheal tube leads to turbulent flow, which increases the airway pressure and resistance. The wall of a wire-reinforced tube is rough compared to a polyvinyl chloride tube and creates friction with air particles, which causes turbulent flow and increases the resistance. In the prone position, a wire-reinforced tube is used to prevent kinking of the endotracheal tube but the neutral position of the head causes the endotracheal tube to curve instead of straighten. This also may cause an increase in R
aw.
The total respiratory resistance is proportional to PIP - P
plat and inversely proportional to the inspiratory flow rate [
19]. In this study, the inspiratory flow rate was kept at a constant rate. Hence, an increase in R
aw increased the difference between the PIP and P
plat. In addition, C
dyn can be found by dividing the tidal volume by PIP. Thus, the increase in C
dyn can be explained as an increase in R
aw.
Backofen and Schauble [
20] and Yokoyama et al. [
21] reported that changing the patient to the prone position decreases the cardiac index (24.4% and 17.2%) and increases the total systemic vascular resistance. The decrease in cardiac index is due to a decrease in venous circulation from venostasis in the leg and an increase in thoracic pressure. However, the change in blood pressure is not commonly the result of an increase in total systemic vascular resistance due to activation of the sympathetic nervous system following a decrease in cardiac output [
22]. These results also showed no significant changes in blood pressure or heart rate in either the supine or prone position.
The prone position for patients with acute respiratory failure is well-known for improving hypoxia and aiding in the correction of V/Q mismatching [
23]. On the other hand, only a few studies have examined the changes in oxygenation and V/Q matching under general anesthesia. Lumb and Nunn [
24] reported that the prone position for normal, conscious patients increases their functional residual capacity. Pelosi et al. [
5] stated that changing to the prone position under general anesthesia increases the functional residual capacity and PaO
2. Previously, pulmonary blood flow was more in the dependent area than in the independent area [
25]. However, magnetic resonance imaging measurements in recent animal studies showed that the pulmonary blood flow moves towards an independent area of the back regardless of the change to the prone position [
26,
27]. This was explained as being due to the structurally low pulmonary vascular resistance of the lung's side towards the back rather than the effects of gravity on pulmonary blood flow. In the prone position, the structural characteristics of the airway and pulmonary vein, rather than the effects of ventilation or gravity, allows for better ventilation in the back area. When changing from the supine to prone position, such an increase in lung volume and improvement in the V/Q matching are known to improve oxygenation [
4]. In the present study, PaO
2 and PaCO
2 differed from the mean values but the changes were not significant. The values were taken 10 minutes after changing to the prone position but these values should have been taken after a longer time had passed.
In conclusion, when changing the patient from the supine to prone position, the PIP can increase even when pressure on the abdomen is minimized using a Jackson surgical table. This is not only because of the decrease in pulmonary and chest wall compliance but also from the effects of the increase in Raw. Therefore, the increase in PIP on patient monitoring should not be attributed only to a decrease in compliance caused by the prone position, but also to an increase in Raw caused by the drainage of secretive fluids due to gravity from the change in body position, as well as to the location and kinking of the endotracheal tube.