Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 1982;15(1):20-24.
DOI: https://doi.org/10.4097/kjae.1982.15.1.20   
The Effects of Nitrous oxide-Nareotic Anesthesia and Surgery on Plasma Aldosterone Level.
Ik Johng Sohn, Jae Chul Shin
1Department of Anesthesiology, College of Medicine, Korea University, Seoul, Korea.
2Department of Anesthesiology, College of Medicine, Chosun University, Kwangju, Korea.
Abstract
This study was performed to investigate the effects of nitrous oxide-narcotic anesthesia (Nitrous oxide-pethidine HCI-muscle relaxant) and surgery on plasma aldosterons level in surgical patients and the aldosterone level in plasma was measured by the Abbott Laboratorie's Aldosterone RIA Kit. Average body weights and ages of subjects were 58.1+/-6.45(kg) and 43.8+/-11.55(yrs) respectively. Mean control aldosterone level in plasma was 121.3+/-58.66I(pg/ml) (mean +/- SE) but it gradually rose during anesthesia and surgery. The mean plasma aldosterone level rose to 232.7+/-40.06(pg/ml) (p<0.005) at 90 minutes after the start of surgery, and therefore, it was a significantly higher value than that of the control.


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
(서울특별시 마포구 마포대로 109 롯데캐슬 프레지던트 101동 3503호)
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists (대한마취통증의학회)
Business Registration: 106-82-07194
Representative: Jun Heum Yon (연준흠)