Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 2006;50(4):478-481.
DOI: https://doi.org/10.4097/kjae.2006.50.4.478   
Pneumothorax during Ventriculoperitoneal Shunt Operation: A case report.
Soo Kyung Lee, Han Seok Kim, Hynu Soo Moon
Department of Anesthesiology and Pain Medicine, Hallym University Sacred Heart Hospital, College of Medicine, Hallym University, Anyang, Korea. hysomoon@yahoo.co.kr
Abstract
Ventriculoperitoneal shunts are currently believed to be a safe standard therapy for hydrocephalus. However, these procedures have been associated with many complications such as infections, ascites, abdominal visceral perforation, and hydrothorax etc. We report an extremely rare complication during a right ventriculoperitoneal shunting for a 70-year male patient. The patient developed tachycardia, hypoxemia, hypercapnia, and an increased airway pressure after inserting the shunt device into the peritoneal cavity. The emergency chest X-ray revealed a right pneumothorax, which was relieved by chest tube air drainage.
Key Words: pneumothorax; ventriculoperitoneal shunt