Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 2006;50(5):495-500.
DOI: https://doi.org/10.4097/kjae.2006.50.5.495   
Effect of Fresh Gas Flow on the Work of Breathing of Closed Circuit Anesthesia Using Semiclosed Circuit System.
Hae Sun You, Young Sun Seo, Hye Won Shin, Hye Won Lee, Hae Ja Lim, Seong Ho Chang, Suk Min Yoon
Department of Anesthesiology and Pain Medicine, College of Medicine, Korea Unversity, Seoul, Korea. ysmin@korea.ac.kr
Abstract
BACKGOUND: The effect of anesthetic techniques, such as closed circuit anesthesia (CCA) using semiclosed circuit system and semiclosed circuit anesthesia (SCCA), on the work of breathing has not been studied yet in detail. This study was purposed to compare the work of breathing according to anesthetic technique (CCA, SCCA).
METHODS
Thirty patients were assigned to receive either SCCA group or CCA group (n = 15). Anesthesia was induced with propofol 2 mg/kg with 2% lidocaine 1 ml. Two percents isoflurane with O2 and N2O 2 L/min were given for 10 min to patients initially to wash in functional residual capacity and the breathing circuits. In SCCA group, anesthesia was maintained with 2% isoflurane in O2 2 L/min and N2O 2 L/min throughout the surgery. In CCA group, O2 was reduced to 200 ml/min and N2O to 100 ml/min with isoflurane vaporizer setting adjusted to 4% for anesthesia maintenance. When the operation was ended, the vaporizer setting of isoflurane deceased to zero and then O2 was increased to 4 L/min for the arousal of the patient. We measured the inspiratory/expiratory concentration of isoflurane, end-tidal CO2, the hemodynamic parameters, the change of airway pressure, the work of breathing, and compliance at anesthetic induction and emergence in both groups.
RESULTS
There were no significant differences in the inspiratory/expiratory concentrations of isoflurane, the hemodynamic parameters, end-tidal CO2, airway pressure, the work of breathing and compliance between the groups.
CONCLUSIONS
CCA using semiclosed circuit system does not increase the work of breathing compared to SCCA.
Key Words: closed circuit anesthesia; isoflurane; semi-closed circuit anesthesia; work of breathing


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
(서울특별시 마포구 마포대로 109 롯데캐슬 프레지던트 101동 3503호)
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists (대한마취통증의학회)
Business Registration: 106-82-07194
Representative: Jun Heum Yon (연준흠)

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next