Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 1999;37(6):961-965.
DOI: https://doi.org/10.4097/kjae.1999.37.6.961   
Two-dimensional Ultrasound-guided Cannulation of the Internal Jugular Vein.
Jie Ae Kim, Chang Joon Ro, Chung Soo Kim, Mi Sook Gwak, Ik Soo Chung, Byeong Mun Hwang
1Department of Anesthesiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
2Department of Anesthesiology, Seoul National University College of Medicine, Seoul, Korea.
Abstract
BACKGROUND
Internal jugular vein access is an essential part of patient management in many clinical settings and is usually achieved with a blind, anatomical landmark-guided technique. The purpose of this study is to evaluate whether a 2-dimensional ultrasound technique can improve on the traditional method.
METHODS
Eighty patients undergoing elective open heart surgery were randomly assigned to an anatomical landmark group or ultrasound group (each n = 40). With the patient in the supine position, the head was rotated 30o to the contralateral side and triangle formed by the clavicle and both heads of the sternocleidomastoid muscle were identified. We accessed the internal jugular vein from the apex of the triangle toward the ipsilateral nipple in the anatomical landmark group. The internal jugular vein and carotid artery were visualized with two-dimensional ultrasound. We compared the number of advances made with the central venous cannulation needle, the time to blood aspiration, complications and failure rate.
RESULTS
The failure rate was 22.5% using the anatomical landmark technique and 5% using the ultrasound technique. The vein was entered on the first attempt in 60% of patients using the landmark technique and in 63% using ultrasound (P>0.05). Mean attempts for puncture were 1.9 (anatomical) vs 1.6 (ultrasound-guided) (P>0.05). Complications occurred in 20% of cases using anatomical landmarks and in 5% using ultrasound (P>0.05). The average access time was 26.5 seconds by the anatomical approach and 56 seconds by the ultrasound approach (P< 0.05).
CONCLUSIONS
Ultrasound-guided cannulation of the internal jugular vein did not significantly decrease failure rate, access time, complications, and attempts for puncture, nor did it increase the amount of successful first attempts. However an investigation using a larger number of patients will be needed.
Key Words: Equipment, catheters, central venous; Measurement techniques, ultrasound


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next