Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 1999;37(6):986-994.
DOI: https://doi.org/10.4097/kjae.1999.37.6.986   
Adequate Target Concentration of Propofol and Fentanyl for Total Intravenous Anesthesia by Target-controlled Infusion during Cesarean Section.
Sang Kee Min, Eun Sook Yoo, Jin Su Kim, Sang Hyun Kim, Sang Gun Han
Department of Anesthesiology, Ajou University School of Medicine, Suwon, Korea.
Abstract
BACKGROUND
Propofol has been used for the induction and maintenance of obstetric anesthesia for its potential benefit of rapid recovery and less post-anesthetic complications. In order to determine the safe application of target-controlled infusion of propofol and fentanyl during Cesarean section under general anesthesia, we have investigated the adequate target concentrations of each drug using the bispectral index and hemodynamic parameters.
METHODS
Ninety-two pregnant women who received Cesarean section under general anesthesia were enrolled in this study. After preoxygenation, anesthesia was induced with thiopental 4 mg/kg and succinylcholine 1 mg/kg, and intubation was done. Vecuronium 0.1mg/kg I.V. was applied for muscle relaxation, and mechanical ventilation was maintained with N2O/O2 (2 L/2 L)-enflurane. EtCO2 was maintained between 30 35 mmHg. After delivery of the fetus, propofol and fentanyl was infused by a computer-assisted continuous infusion system with air/O2 (2 L/2 L). The bispectral index was monitored perioperatively. This study proceeded in three stages. In the first stage, thirty women were studied for titration of the target effect-site concentration of propofol that could maintain a bispectral index between 40 60 while maintaining the target concentration of fentanyl at 1.5 ng/ml. In the second stage, forty-two women were randomly assigned into the four different groups (F25, F50, F75, F100) at target fentanyl concentrations of fentanyl of 0.25, 0.50, 0.75 and 1.0 ng/ml for each group respectively. The adequate target concentration of fentanyl was titrated. In the third stage, twenty women were studied for assessment of the adequacy of target concentrations of propofol and fentanyl prospectively.
RESULTS
The target effect-site concentrations (Ce, 95% confidence interval) that could maintain 50% and 95% of patients hemodynamically stable with the bispectral index within 40-60 were 2.41 (2.27-2.55) microgram/ml and 3.15 (2.95-3.50) microgram/ml for propofol, 0.32 (0.13-0.46) ng/ml and 0.84 (0.66-1.29) ng/ml for fentanyl. The pre-anesthetic bispectral index was 97.1+/-1.2 and it decreased maximally to 39.5+/-6.47 after thiopental injection and increased maximally to 83.6+/-6.3 before delivery and it was 80.6+/-6.9 for eye-open to verbal command during recovery.
CONCLUSIONS
The adequate target effect-site concentrations of propofol and fentanyl for the maintenance of total intravenous anesthesia during Cesarean section were determined and these concentrations were validated prospectively.
Key Words: Anesthesia, target-controlled infusion; Anesthetics, intravenous, fentanyl, propofol; Monitoring, bispectral index; Surgery, obstetrics, Cesarean section


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next