Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 2000;38(3):537-545.
DOI: https://doi.org/10.4097/kjae.2000.38.3.537   
Comparisons between Classic Shunt and Non-Invasive Shunt in One-Lung Ventilated and Hemodiluted Dogs.
Woon Seok Roh, Hyun Chul Joo, Chan Hong Park, Bong Il Kim, Soung Kyung Cho, Sang Hwa Lee
Department of Anesthesiology, School of Medicine, Catholic University of Taegu Hyosung, Taegu, Korea.
Abstract
BACKGROUND
As the clinical application of non-invasive shunt estimation to operation under one-lung ventilation has not been reported, this study was carried out to evaluate the validity and accuracy of the non-invasive shunt estimations in one-lung ventilation with hemodilution.
METHODS
Following general anesthesia with enflurane 0.5 1 vol.% and 100% oxygen in ten Mongrel dogs (B.W. around 16 kg), tracheostomy and insertion of left-side endobronchial tube and one-lung ventilation were performed. Acute normovolemic hemodilution was produced by sequential hemodilution with hydroxyethyl starch. The intrapulmonary shunt (QS/QT) was calculated by the classic shunt equation, by the oxygen contents-based estimated shunt equation, and by oxygen tension-based estimations such as alveolar to arterial oxygen difference (P(A-a)O2), respiratory index (RI, P(A-a)O2/PaO2), arterial oxygen tension to alveolar oxygen ratio (PaO2/PAO2), and PaO2 to FiO2 ratio. To assess the quantitative accuracy of the estimated shunt, the data were divided arbitrarily into two groups on the basis of the mean arteriovenous oxygen content difference (C(a-v)O2) being 3.6 ml/dl or greater (group 1) and less than 3.6 ml/dl (group 2). Relationships to QS/QT were analyzed by simple linear regression.
RESULTS
In 104 measurements, the correlation between QS/QT and non-invasive shunt were poor (r = 0.66 - 0.76). However, in group 1 (n = 45), the correlation between QS/QT and the estimated shunt were very good (r = 0.93) and good for P(A-a)O2 (r = 0.83), RI (r = 0.87), PaO2/PAO2 (r = - 0.84), and PaO2/FiO2 (r = - 0.85). In group 2 (n = 58), the correlation between QS/QT and non-invasive shunt were worse than in group 1. Group 2 had lower hematocrit (20.6% vs 26.7 %, P < 0.001), higher cardiac output, and lower pulmonary and systemic vascular resistance than group 1 (P < 0.05). The difference between the estimated shunt and the classic shunt in group 1 remained constant when the classic shunt was increased further. However, the difference in group 2 was enhanced by the increment of the classic shunt.
CONCLUSIONS
We conclude that even if the non-invasive shunt estimation might be affected by hemoglobin and cardiac output, it is a viable method in mild hemodiluted patients with good cardiovascular reserve.
Key Words: Lung: shunting; Ventilation: one-lung
TOOLS
Share :
Facebook Twitter Linked In Line it
METRICS Graph View
  • 0 Crossref
  •    
  • 1,184 View
  • 6 Download


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next