Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 2000;39(4):578-582.
DOI: https://doi.org/10.4097/kjae.2000.39.4.578   
Reliability of Noninvasive Measurement of Cardiac Output Using Partial CO2 Rebreathing: A Comparison with Thermodilution Method.
Kook Hyun Lee, Jie Ae Kim
1Department of Anesthesiology, College of Medicine, Seoul National University, Seoul, Korea.
2Department of Anesthesiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Abstract
BACKGROUND
A noninvasive method for estimating cardiac output was tested in dogs. The technique is based on a differential CO2 Fick equation applied during normal ventilation and 50 seconds of partial rebreathing using additional dead space. We compared the cardiac output measured by the CO2 rebreathing method vs. the thermodilution technique.
METHODS
Seven mongrel-dogs (24.6 +/- 0.4 kg) were studied, anesthesia was induced and maintained with a pentobarbital 25 mg/kg IV bolus injection followed by an infusion of 5 mg/kg/h. Mechanical ventilation was accomplished with a Servo 900C ventilator with FiO2 0.6 to maintain normocarbia. A fiberoptic pulmonary artery catheter was introduced via an external jugular vein for continuous monitoring of the cardiac output by the thermodilution method. Also cardiac output was measured by using partial CO2 rebreathing method. A continuous infusion of 0.5% bupivacaine was started at 0.5 mg/kg/min via the venous infusion port of the pulmonary catheter. Bupivacaine was infused continuously until mean arterial pressure decreased to 60 mmHg or less for at least 5 seconds.
RESULTS
The total measured cardiac outputs (n = 72) were distributed over the range of 1.03-7.72 L/min by thermodilution method and 1.6-7.3 L/min by CO2 rebreathing. The correlation coefficients between both cardiac outputs was 0.6, the mean difference was 0.27 +/- 0.81 L/min.
CONCLUSIONS
The cardiac output measured by CO2 rebreathing method was well correlated with cardiac output by thermodilution method.
Key Words: Measurement techniques: cardiac output; partial CO2 rebreathing method; thermodilution method
TOOLS
Share :
Facebook Twitter Linked In Line it
METRICS Graph View
  • 1 Crossref
  •    
  • 1,385 View
  • 6 Download


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next