Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 2001;40(6):695-699.
DOI: https://doi.org/10.4097/kjae.2001.40.6.695   
Comparison of Systolic Pressure Variation and Plethysmographic Pulse Wave Variation of a Pulse Oximeter.
Chee Mahn Shin, Se Hun Lim, Jeong Hun Kim, Soon Ho Jeong, Joung Kyun Choe, Young Jae Kim, Jin Woo Park, Ju Yuel Park
Department of Anesthesiology, College of Medicine, Inje University, Busan, Korea.
Abstract
BACKGROUND
Maintenance of volume status and treatment of hypovolemia constitute an important component of anesthetic management. A Pulse oxymeter providing a continuous display of the pulse waveform offers a new method of estimating relative volume status during positive pressure ventilation. This study was undertaken to use the pulse wave variance of a plethysmographic signal measured from a pulse oximeter as a useful tool in the assessment of volume status.
METHODS
Forty patients underwent general anesthesia with controlled positive pressure ventilation. After induction, the fluid infusion rate was 100 cc/hr until the dura was opened. During the operation, fluid losses were not replaced until hemodynamic variables were printed out. In addition to standard monitoring,the arterial pressure was monitored with a radial artery catheter. Systolic pressure variation (SPV) was defined as the maximum variation in peak systolic pressure during the respiratory cycle and measured in mmHg. Plethysmographic pulse wave variation (PWV) was defined as the maximum variation in the waveform peaks during the respiratory cycle and measured in millimeters from the printed output of the pulse oximeter. SPV and PWV were printed out right after induction and right before dura opening. In addition to SPV and PWV, other hemodynamic variables (HR, MAP, CVP) were obtained.
RESULTS
Heart rate, SPV and PWV increased before the dura opening compared with those after induction. PWV correlated well with SPV after fluid losses CONCLUSIONS: A Pulse oximeter which is a standard monitor in anesthesia provides a useful, noninvasive and inexpensive adjunct to the more invasive estimators of volume status.
Key Words: Blood volume: hypovolemia; Monitoring: plethysmographic pulse wave variance; systolic pressure variance


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next