Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 1993;26(1):161-164.
DOI: https://doi.org/10.4097/kjae.1993.26.1.161   
Accidental Insertion of Entire Guide - Wire in the Inferior Vena Cava During Central Venous Catheterization.
Young Bok Lee, Kyoung Min Lee, Kwang Ho Lee, Dae Ja Um
Department of Anesthesiology, Yonsei University, Wonju College of Medicine, Wonju, Korea.
Abstract
Complications during central venous catheterization are well recognized and include infection, air emboliam, hemorrhage, pneumothorax and extravascular migration of central venous .catheter. The over-wire technique is usually considered safe. However, the wire itself can eause complications by looping knotting and retention. We ecperienced a case of accidental insertion of entire guide-wire during central venous catheterization via the right interal jugular vein. The right femoral vein was cannulated and the guide-wire was removed by a PIG TAIL catheter under the fluoroscopy.
Key Words: Catheterization; Guide-wire; Accidental insertion