Korean Journal of Anesthesiology 2007;53(2):194-198.
DOI: https://doi.org/10.4097/kjae.2007.53.2.194   
The Change of Arterial Blood Gas during Endoscopic Saphenous Vein Harvesting for Coronary Artery Bypass Grafting.
Ji Min Chang, Cheol Min Song, Jun Heum Yon, Sang Seok Lee, Byung Hoon Yoo, Dong Uk Kang
1Department of Anesthesiology and Pain Medicine, Sanggye Paik Hospital, College of Medicine, Inje University, Seoul, Korea. twowind@sanggyepaik.ac.kr
2Department of Thoracic and Cardiovascular Surgery, Sanggye Paik Hospital, College of Medicine, Inje University, Seoul, Korea.
Abstract
BACKGROUND
Endoscopic surgical procedure has recently been applied to not only intraabdominal or intrathoracic surgery but also saphenous vein harvesting, because it is less invasive and more cosmetically advantageous. Carbon dioxide insufflation during an endoscopic saphenous vein harvesting may cause an adverse effects on arterial blood gas and hemodynamic variables. This study was conducted to evaluate the safety of carbon dioxide insufflation during endoscopic saphenous vein harvesting.
METHODS
Patients in ASA physical status III or IV, scheduled for an endoscopic saphenous vein harvesting (n=30) were gathered for the evaluation. Until the end of the procedure, controlled mechanical ventilation (tidal volume: 10 ml/kg, respiratory rate: 10 rates/min) and ventilator mode was fixed in this tidal volume and respiratory rate. Arterial blood gas analysis, end-tidal carbon dioxide, blood pressure and heart rate were measured before and at 10, 20, 30, 40 minutes after carbon dioxide insufflation.
RESULTS
Preinsufflation values of PaCO2 (partial pressure of arterial carbon dioxide) and PETCO2 (partial pressure of end-tidal carbon dioxide) were 33.4 +/- 3.6 mmHg and 24.1 +/- 4.1 mmHg, respectively. PaCO2 was significantly increased at 30 and 40 minutes after carbon dioxide insufflation (40.1 +/- 7.4 mmHg and 41.4 +/- 8.6 mmHg). PETCO2 was significantly increased at 20, 30 and 40 minutes after carbon dioxide insufflation(27.6 +/- 5.5 mmHg, 28.9 +/- 7.0 mmHg and 29.6 +/- 7.8 mmHg). But, the magnitude of difference between PaCO2 and PETCO2 was not significantly different.
CONCLUSIONS
During endoscopic saphenous vein harvesting, PaCO2 was significantly increased compared with preinsufflation values. Careful monitoring of PaCO2 is mandatory during the procedure.
Key Words: arterial blood gas; coronary artery bypass grafting; endoscopic surgical procedure; saphenous vein


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next