Hypercapnia Due to Unrecognized Recurarization with a High Oxygen Saturation on the Pulse Oximeter.
Kyo Sang Kim, Hwa Nyon Kim, Hee Young Cho, Dong Won Kim
Department of Anesthesiology, College of Medicine, Hanyang University, Seoul, Korea. kimks@hanyang.ac.kr
Abstract
Carbon dioxide narcosis can produce apnea and coma, even though blood oxygen remains high enough to sustain life. We reported an unusual case of hypercapnia due to unrecognized recurarization with a high oxygen saturation on the pulse oximeter. A 74 year-old woman was scheduled for a spinal fusion due to a fracture of the lumbar vertebrae. During more than an hour after surgery, the oxygen saturation on the pulse oximeter was 99 or 100%. Neostigmine was repeatedly required due to only one twitch of train-of-four (TOF) stimulation at that time. Despite a return of four twitchs of TOF stimulation, the patient's level of consciousness deteriorated as a result of hypercapnia (PaCO2: 92.3 mmHg). Reventilation was required until this unusual carbon dioxide store had dissipated. We discuss the investigation, diagnosis and subsequent management of such an old patient and emphasize that the TOF stimulation was a reliable indicator of adequate recovery of neuromuscular function.
Key Words: Carbon dioxide; complications; hypercapnia; recurarization


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
(서울특별시 마포구 마포대로 109 롯데캐슬 프레지던트 101동 3503호)
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists (대한마취통증의학회)
Business Registration: 106-82-07194
Representative: Jun Heum Yon (연준흠)

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next