Korean J Anesthesiol > Volume 39(6); 2000 > Article
Korean Journal of Anesthesiology 2000;39(6):780-785.
DOI: https://doi.org/10.4097/kjae.2000.39.6.780   
Clinical Application of Laryngeal Mask Airway in Cesarean Section.
Eun Jung Chung, Hong Seuk Yang, Byung Tae Suh
Department of Anesthesiology, Asan Medical Center, College of Medicine, University of Ulsan, Seoul, Korea.
Abstract
BACKGROUND
Laryngeal mask airway (LMA) is a useful instrument for routine anesthesia. It permits spontaneous or positive pressure ventilation but its use in obstetric anesthesia has not been described. In this study, we evaluated the effectiveness and the side effects of the LMA during elective cesarean sections. METHODS: Institutional approval and patients' permission were obtained. One thousand sixty-seven patients scheduled for elective an cesarean section, that have been NPO for more than 6 (6-48) hours were evaluated. They were premedicated with an H2 receptor blocker (ranitidine 50 mg i.m.) 1 hour before the operation. They were anesthetized with penthotal sodium (3-4 mg/kg), vecuronium (1 mg/10 kg i.m.) and then a 3 or 4 LMA was inserted after the mask ventilation with 100% oxygen for 1 min. The cuff was inflated with air 15.3 +/- 2.6 ml. On auscultation, air entry was good in both lungs. Anesthesia was maintained by 50% oxygen in N2O with 0.7 - 1.0% enflurane. Analgesics (tramadol 30 mg i.v.) was given incrementally after delivery of the baby. Manual assisted ventilation was used throughout the procedure. The number of insertion attempts, cuff volume and the incidences of complications were evaluated. RESULTS: In 1051 patients, the LMA was inserted on the first attempt. In 16 patients more than 2 attempts were needed and change to endotracheal intubation were needed in 7 cases. The mean cuff volume was 15 +/- 2.6 ml at insertion and increased to 18.5 +/- 3.2 ml after removal. The average airway pressure was 20 cmH2O during positive pressure ventilation, above that pressure air leakage was detected in 16 cases. Complications noted were mild sore throat in 5 cases, and blood tinged after removal of LMA in 3 cases but gastric distention was not detected. No incidence of aspiration was noted. CONCLUSIONS: In this study, the LMA proved to be a useful tool for the management of patients presenting for elective an cesarian section. There is the remote possibility of aspiration which did not happen in our study.
Key Words: Anesthesia: general; obstetric; Equipment: airway; laryngeal mask airway
TOOLS
Share :
Facebook Twitter Linked In Line it
METRICS Graph View
  • 0 Crossref
  •    
  • 849 View
  • 20 Download


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2022 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next