Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 1994;27(7):816-823.
DOI: https://doi.org/10.4097/kjae.1994.27.7.816   
The Effects of Laryngeal Mask Airway Placement and Tracheal Intubation on Intraocular Pressure.
Sang Kyi Lee, Jae Yang Kim, He Sun Song
Department of Anesthesiology, School of Medicine, Chonbuk University, Chonju, Korea.
Abstract
Many studies have been performed in order to evaluate intraocular pressure changes during induction and maintenance of anesthesia in ocular surgery. Use of the laryngeal mask airway permits the maintenance of a clear airway without laryngoscopy. To evaluate the effect of laryngeal mask airway placement with/withaut laryngoscopy on intraocular pressure, sixty patients were randomly allocated to one of three groups; a tracheal intubation group with laryngoscopy (TI, n=20); a laryngeal mask airway placement group with laryngoscopy (LMA-L, n=20); a laryngeal mask airway placement group with blind technique (LMA, n=20). The authors compared the intraocular pressure and hemodynamic responses to the laryngeal mask airway insertion with (LMA-L group) and without (LMA group) laryngoscope to those of tracheal intubation (TI group) in 60 patients during a standardized anesthetic pratice. Baseline measurements of intrao- cular pressure, heart rate, and arterial blood pressures were recorded and repeated at one minute after insertion of the airway device in each group. Insertion of the laryngeal mask airway required significantly more time (LMA-L group, 15.5 sec; LMA group, 14.3 sec) in comparison with that for the tracheal intubation (9.1 sec). The laryngeal mask airway placement did not increase intraocular pressure, or arterial blood pressures except for heart rate above baseline values. However, tracheal intubation was associated with significant increases of intraocular pressure, heart rate, and arterial blood pressure at one minute compared to the baseline values. The mean intraocular pressures at one minute after airway instrumentation in TI group were significantly different from those of LMA or LMA-L group. The authors suggest that a laryngeal mask airway may be a good alternative to tracheal intubation in intraocular surgery if a laryngeal mask airway is not contraindicated.
Key Words: Laryngeal mask airway; Tracheal intubation; Intraocular pressure


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                

Copyright © 2024 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next