Effects of intravenously administered indocyanine green on near-infrared cerebral oximetry and pulse oximetry readings
Ho Young Baek, Hyun-jung Lee, Joung Min Kim, Soo-young Cho, Seongtae Jeong, Kyung Yeon Yoo
Korean J Anesthesiol. 2015;68(2):122-127.   Published online 2015 Mar 30     DOI: https://doi.org/10.4097/kjae.2015.68.2.122
Citations to this article as recorded by Crossref logo
Augmenting Laparoscopic Surgery with Fluorescence Imaging
Chris Thomson
Veterinary Clinics of North America: Small Animal Practice.2024;[Epub]     CrossRef
Anaesthetic implications of intra-operative Indocyanine Green use in pediatric surgery
Max J Pachl
Photodiagnosis and Photodynamic Therapy.2023; 44: 103817.     CrossRef
Complementary Tools in Cerebral Bypass Surgery
Varun M. Bhave, Lauren E. Stone, Robert C. Rennert, Jeffrey A. Steinberg
World Neurosurgery.2022; 163: 50.     CrossRef
Fluorescence-Guided Surgery (FGS) during a Laparoscopic Redo Nissen Fundoplication: The First Case in Children
Irene Paraboschi, Laura Privitera, Stavros Loukogeorgakis, Stefano Giuliani
Children.2022; 9(7): 947.     CrossRef
Indocyanine Green Administration May Cause an Exaggerated Peripheral Oxygen Desaturation in the Presence of Liver Disease—An Underemphasized Observation
Mukilan Balasubramanian, Ankita Dey, Rajasekar Ramadurai, Aswini Kuberan
Journal of Neuroanaesthesiology and Critical Care.2022; 09(03): 215.     CrossRef
Cerebral oximetry changes “out of the blue”
Jane S. Yu, Christian Seefelder
Pediatric Anesthesia.2020; 30(5): 626.     CrossRef
Fluorescence Imaging Using Indocyanine Green Dye in the Pediatric Population
Shabana Zainab Shafy, Mohammed Hakim, Susan Lynch, Lian Chen, Joseph D. Tobias
The Journal of Pediatric Pharmacology and Therapeutics.2020; 25(4): 309.     CrossRef
Artifactual reduction in oxygen saturation readings affected by indocyanine green in ophthalmic angiography
Mitsuhiro Matsuzaki, Kanako Ishii, Akihiro Nishida, Naohiro Motozawa, Mizuho Fujimori, Mamiko Hamada, Yasuo Kurimoto
Japanese Journal of Ophthalmology.2020; 64(5): 516.     CrossRef
Near-infrared fluorescence laparoscopy of the ureter with three preclinical dyes in a pig model
Jacqueline van den Bos, Mahdi Al-Taher, Nicole D. Bouvy, Laurents P. S. Stassen
Surgical Endoscopy.2019; 33(3): 986.     CrossRef
Near-infrared fluorescence laparoscopy of the cystic duct and cystic artery: first experience with two new preclinical dyes in a pig model
Jacqueline van den Bos, Mahdi Al-Taher, Shu Gi Hsien, Nicole D. Bouvy, Laurents P. S. Stassen
Surgical Endoscopy.2017; 31(10): 4309.     CrossRef
Is NIRS-based Cerebral Oximetry Sufficient Monitoring Modality During ICG Utilization in CEA?
Nitin Manohar, K. R. Madhusudan Reddy, Dhritiman Chakrabarti
Journal of Neurosurgical Anesthesiology.2016; 28(1): 87.     CrossRef
The values shown on optical technology-based patient monitors must be cautiously interpreted: intravenous dye-induced errors
Hee-Pyoung Park
Korean Journal of Anesthesiology.2015; 68(2): 97.     CrossRef