Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy
Kyung Mi Kim, Mi Sook Gwak, Soo Joo Choi, Myung Hee Kim, Mi Hye Park, Burn Young Heo
Korean J Anesthesiol. 2013;65(3):237-243.   Published online 2013 Sep 25     DOI: https://doi.org/10.4097/kjae.2013.65.3.237
Citations to this article as recorded by Crossref logo
The ability of perfusion index and positional perfusion index variation to predict spinal anesthesia-induced hypotension in elderly patients: A prospective observational study
Amr Abdelkader, Mohamed Elshazly, Maged Elgendy, Ahmed Nabih
Perioperative Care and Operating Room Management.2024; 35: 100393.     CrossRef
Reliability of pulse pressure and stroke volume variation in assessing fluid responsiveness in the operating room: a metanalysis and a metaregression
Antonio Messina, Mariagiovanna Caporale, Lorenzo Calabrò, Giulia Lionetti, Daniele Bono, Guia Margherita Matronola, Andrea Brunati, Luciano Frassanito, Emanuela Morenghi, Massimo Antonelli, Michelle S. Chew, Maurizio Cecconi
Critical Care.2023;[Epub]     CrossRef
Correlation between Carotid and Brachial Artery Velocity Time Integral and Their Comparison to Pulse Pressure Variation and Stroke Volume Variation for Assessing Fluid Responsiveness
Praveen Dhakane, Rutuja Phulambrikar
Indian Journal of Critical Care Medicine.2022; 26(2): 179.     CrossRef
Association Between Circular RNAs and Intracranial Aneurysm Rupture Under the Synergistic Effect of Individual Environmental Factors
Qing Huang, Yi Sun, Qiuyu Huang, Yile Zeng, Shaowei Lin, Shuna Huang, Yingying Cai, Xingyan Xu, Dezhi Kang, Huangyuan Li, Siying Wu
Frontiers in Neurology.2021;[Epub]     CrossRef
Monitorización de la variación de la presión de pulso durante la cirugía de resección pulmonar
J.M. Nieves Alonso, E. Alday Muñoz, A. Planas Roca
Revista Española de Anestesiología y Reanimación.2019; 66(2): 78.     CrossRef
Monitoring pulse pressure variation during lung resection surgery
J.M. Nieves Alonso, E. Alday Muñoz, A. Planas Roca
Revista Española de Anestesiología y Reanimación (English Edition).2019; 66(2): 78.     CrossRef
Pre-anesthetic stroke volume variation can predict cardiac output decrease and hypotension during induction of general anesthesia
Takashi Juri, Koichi Suehiro, Sayaka Tsujimoto, Shigemune Kuwata, Akira Mukai, Katsuaki Tanaka, Tokuhiro Yamada, Takashi Mori, Kiyonobu Nishikawa
Journal of Clinical Monitoring and Computing.2018; 32(3): 415.     CrossRef
Predicting fluid responsiveness: A review of literature and a guide for the clinician
Bilal A. Jalil, Rodrigo Cavallazzi
The American Journal of Emergency Medicine.2018; 36(11): 2093.     CrossRef
Fluid Challenge During Anesthesia: A Systematic Review and Meta-analysis
Antonio Messina, Corrado Pelaia, Andrea Bruni, Eugenio Garofalo, Eleonora Bonicolini, Federico Longhini, Erica Dellara, Laura Saderi, Stefano Romagnoli, Giovanni Sotgiu, Maurizio Cecconi, Paolo Navalesi
Anesthesia & Analgesia.2018; 127(6): 1353.     CrossRef
Evaluation of stroke volume variation and pulse pressure variation as predictors of fluid responsiveness in patients undergoing protective one-lung ventilation
Qiang Fu, Mingda Duan, Feng Zhao, Weidong Mi
Drug Discoveries & Therapeutics.2015; 9(4): 296.     CrossRef
Continuous automatic pulse pressure variation: a systematic review and meta-analysis
Heeyoung Bang
Journal of the Korean Medical Association.2015; 58(6): 563.     CrossRef
The correlation between the Trendelenburg position and the stroke volume variation
Jin Hye Min, Sang Eun Lee, Hong Sik Lee, Young Keun Chae, Yong Kyung Lee, Yoo Kang, Ui Jin Je
Korean Journal of Anesthesiology.2014; 67(6): 378.     CrossRef