The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function
Youn Yi Jo, Jong Wook Song, Young Chul Yoo, Ji Young Park, Jae Kwang Shim, Young Lan Kwak
Korean J Anesthesiol. 2011;60(4):237-243.   Published online 2011 Apr 26     DOI: https://doi.org/10.4097/kjae.2011.60.4.237
Citations to this article as recorded by Crossref logo
Vía clínica de recuperación intensificada en cirugía cardiaca. Documento de consenso de la Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor (SEDAR), la Sociedad Española de Cirugía Cardiovascular y Endovascular (SECCE) y la Asociac
M.A. Pajares, J.A. Margarit, C. García-Camacho, J. García-Suarez, E. Mateo, M. Castaño, C. López Forte, J. López Menéndez, M. Gómez, M.J. Soto, S. Veiras, E. Martín, B. Castaño, S. López Palanca, T. Gabaldón, J. Acosta, J. Fernández Cruz, A.R. Fernández L
Revista Española de Anestesiología y Reanimación.2021; 68(4): 183.     CrossRef
Vía clínica de recuperación intensificada en cirugía cardiaca. Documento de consenso de la Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor (SEDAR), la Sociedad Española de Cirugía Cardiovascular y Endovascular (SECCE) y la Asociac
Juan A. Margarit, María Azucena Pajares, Carlos García-Camacho, Mario Castaño-Ruiz, María Gómez, Jessica García-Suárez, María José Soto-Viudez, José López-Menéndez, Elio Martín-Gutiérrez, Juan Blanco-Morillo, Eva Mateo, Carlos Hernández-Acuña, Marc Vives,
Cirugía Cardiovascular.2021; 28: 1.     CrossRef
Guidelines for enhanced recovery after cardiac surgery. Consensus document of Spanish Societies of Anaesthesia (SEDAR), Cardiovascular Surgery (SECCE) and Perfusionists (AEP)
M.A. Pajares, J.A. Margarit, C. García-Camacho, J. García-Suarez, E. Mateo, M. Castaño, C. López Forte, J. López Menéndez, M. Gómez, M.J. Soto, S. Veiras, E. Martín, B. Castaño, S. López Palanca, T. Gabaldón, J. Acosta, J. Fernández Cruz, A.R. Fernández L
Revista Española de Anestesiología y Reanimación (English Edition).2021; 68(4): 183.     CrossRef
Guidelines for enhanced recovery after cardiac surgery. Consensus document of Spanish Societies of Anesthesia (SEDAR), Cardiovascular Surgery (SECCE) and Perfusionists (AEP)
Juan Antonio Margarit, Maria Azucena Pajares, Carlos Garcia Camacho, Mario Castaño Ruiz, Maria Gómez, Jessica García Suárez, María José Soto, José López Meléndez, Elio Martín Gutiérrez, Juan Blanco Morillo, Evaº Mateo, Carlos Hernández Acuña, Marc Vives,
Revista Española de Perfusión.2020; (Supplement): 5.     CrossRef
Estimation of Cardiac Index: Validation of the Mobil-O-Graph NG in Comparison with the FloTrac/Vigileo
Ho Bum Cho, Sun Young Park, So Jin Na, Hyerim Kwon, Jae Hwa Yoo, Mun Gyu Kim, Ji-Won Chung, Sang Ho Kim
Soonchunhyang Medical Science.2018; 24(2): 160.     CrossRef
Accuracy and Trending Ability of the Fourth-Generation FloTrac/Vigileo System in Patients With Low Cardiac Index
Kohshi Hattori, Takuma Maeda, Tetsuhito Masubuchi, Atsushi Yoshikawa, Keigo Ebuchi, Kuniko Morishima, Masataka Kamei, Kenji Yoshitani, Yoshihiko Ohnishi
Journal of Cardiothoracic and Vascular Anesthesia.2017; 31(1): 99.     CrossRef
Accuracy, Precision, and Trending Ability of Uncalibrated Arterial Pressure Waveform Analysis of Cardiac Output in Patients With Impaired Left Ventricular Function: A Prospective, Observational Study
Leonard J. Montenij, Johannes P. Sonneveld, Arno P. Nierich, Wolfgang F. Buhre, Eric E. De Waal
Journal of Cardiothoracic and Vascular Anesthesia.2016; 30(1): 115.     CrossRef
Calibrated versus uncalibrated arterial pressure waveform analysis in monitoring cardiac output with transpulmonary thermodilution in patients with severe sepsis and septic shock
Cornelis Slagt, Mochamat Helmi, Ignacio Malagon, A.B. Johan Groeneveld
European Journal of Anaesthesiology.2015; 32(1): 5.     CrossRef
Systematic review of uncalibrated arterial pressure waveform analysis to determine cardiac output and stroke volume variation
C. Slagt, I. Malagon, A.B.J. Groeneveld
British Journal of Anaesthesia.2014; 112(4): 626.     CrossRef
The Vigileo-FloTracTM System: Arterial Waveform Analysis for Measuring Cardiac Output and Predicting Fluid Responsiveness: A Clinical Review
Koichi Suehiro, Katsuaki Tanaka, Tadashi Matsuura, Tomoharu Funao, Tokuhiro Yamada, Takashi Mori, Kiyonobu Nishikawa
Journal of Cardiothoracic and Vascular Anesthesia.2014; 28(5): 1361.     CrossRef
Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis
Thomas Schlöglhofer, Hermann Gilly, Heinrich Schima
Canadian Journal of Anesthesia/Journal canadien d'anesthésie.2014; 61(5): 452.     CrossRef
Noninvasive Cardiac Output Monitors: A State-of the-Art Review
Paul E. Marik
Journal of Cardiothoracic and Vascular Anesthesia.2013; 27(1): 121.     CrossRef
Comparative study of pressure- and volume-controlled ventilation on stroke volume variation as a predictor of fluid responsiveness in patients undergoing major abdominal surgery
Ji Yeon Lee, Hee Yeon Park, Wol Seon Jung, Youn Yi Jo, Hyun Jeong Kwak
Journal of Critical Care.2012; 27(5): 531.e9.     CrossRef
Arterial waveform analysis in anesthesia and critical care
Leon J. Montenij, Eric E.C. de Waal, Wolfgang F. Buhre
Current Opinion in Anaesthesiology.2011; 24(6): 651.     CrossRef