Korean J Anesthesiol Search

CLOSE


Previous issues

  • HOME
  • BROWSE ARTICLES
  • Previous issue
Volume 74(3); Jun 2021
Editorial
Determinants for the duration of a single-shot interscalene brachial plexus block: concentration vs. volume of local anesthetics
Seong-Hyop Kim
Korean J Anesthesiol. 2021;74(3):189-190.   Published online May 13, 2021
Review Articles
Anesthetics or anesthetic techniques and cancer surgical outcomes: a possible link
Azeem Alam, Sanketh Rampes, Sonam Patel, Zac Hana, Daqing Ma
Korean J Anesthesiol. 2021;74(3):191-203.   Published online February 17, 2021
As of 2018 cancer is responsible for almost 9.6 million deaths annually and, with an aging population, the incidence of cancer is expected to continue to rise. Surgery is an important treatment modality for patients with solid organ cancers. It has been postulated that, due to potentially overlapping processes underlying the development of malignancy and the therapeutic pathways of various anesthetic agents, the choice of anesthetic type and method of administration may affect post-operative outcomes in patients with cancer. This is a literature review of the most recent evidence extracted from various databases including PubMed, EMBASE, and the Cochrane, as well as journals and book reference lists. The review highlights the pathophysiological processes underpinning cancer development and the molecular actions of anesthetic agents, pre-clinical and retrospective studies investigating cancer and anesthetics, as well as ongoing clinical trials. Overall, there are conflicting results regarding the impact of regional vs. general anesthesia on cancer recurrence, whilst the majority of data suggest a benefit of the use of intravenous propofol over inhalational volatile anesthetics. The biological changes associated with the surgical inflammatory response offer a unique opportunity to intervene to counteract any potentially cancer-promoting effects.
Interpretation of volume kinetics in terms of pharmacokinetic principles
Byung-Moon Choi
Korean J Anesthesiol. 2021;74(3):204-217.   Published online March 5, 2021
Volume kinetics is the pharmacokinetics of infusion fluids and describes the distribution and elimination of infused volume. Generally, pharmacokinetic parameters can be estimated by measuring the concentration of a drug. However, it is almost impossible to directly measure the concentration of fluids. Therefore, in volume kinetics, the disposition of fluids is indirectly quantified by measuring the hemoglobin concentration under the premise of no hemoglobin loss. If the hemoglobin concentration is repeatedly measured while administering the fluids, the dilution (relative change of the plasma volume) for each corresponding hemoglobin concentration can be obtained. The dilution is based on the concept of plasma volume expansion. The method of quantifying the drugs disposition with compartmental analysis has been equally applied to volume kinetics. The transfer of fluids between compartments is explained by first-order kinetics, and it is assumed that fluid is only removed from the central compartment. Population analysis can be used to identify covariates that can account for inter-individual variability in volume kinetic parameters. Body weight and mean blood pressure are well-known representative covariates of kinetic volume parameters. Using volume kinetic parameters, the volume expansion effects of crystalloid and colloid solutions can be understood more effectively, thereby facilitating appropriate fluid therapy. Although limitations exist in volume kinetics, its implications are important for clinicians when administering fluids.
Clinical Research Articles
A comparison of the breathing apparatus deadspace associated with a supraglottic airway and endotracheal tube using volumetric capnography in young children
Eduardo Javier Goenaga-Diaz, Lauren Daniela Smith, Shelly Harrell Pecorella, Timothy Earl Smith, Gregory B Russell, Kathleen Nicole Johnson, Martina Gomez Downard, Douglas Gordon Ririe, Dudley Elliott Hammon, Ashley Sloan Hodges, Thomas Wesley Templeton
Korean J Anesthesiol. 2021;74(3):218-225.   Published online November 17, 2020
Background
Supraglottic airway (SGA) devices including the air-Q® are being used with increasing frequency for anesthesia in infants and younger pediatric patients. To date, there is minimal research documenting the potentially significant airway deadspace these devices may contribute to the ventilation circuit when compared to an endotracheal tube (ETT). The aim of this study was to evaluate the airway apparatus deadspace associated with an air-Q® versus an ETT in young children.
Methods
In a prospective cohort study, 59 patients between 3 months and 6 years of age, weighing between 5 and 20 kg, scheduled for outpatient urologic or general surgery procedures were recruited. An air-Q® or ETT was inserted at the discretion of the attending anesthesiologist, and tidal volume, positive end expiratory pressure, respiratory rate, and end-tidal CO2 were controlled according to protocol. Airway deadspace was recorded using volumetric capnography every 2 min for 10 min.
Results
Groups were similar in demographics. There was a significant difference in weight-adjusted deadspace volume between the air-Q® and ETT groups, 4.1 ± 0.8 ml/kg versus 3.0 ± 0.7 ml/kg, respectively (P < 0.001). Weight-adjusted deadspace volume (ml/kg) increased significantly with decreasing weight for both the air-Q® and ETT groups.
Conclusions
In healthy children undergoing positive pressure ventilation for elective surgery, the air-Q® SGA introduces significantly greater airway deadspace than an ETT. Additionally, airway deadspace, and minute ventilation required to maintain normocarbia, appear to increase with decreasing patient weight irrespective of whether a SGA or ETT is used.
Comparison between two different concentrations of a fixed dose of ropivacaine in interscalene brachial plexus block for pain management after arthroscopic shoulder surgery: a randomized clinical trial
Seung Cheol Lee, Joon Ho Jeong, Seong Yeop Jeong, Sung Wan Kim, Chan Jong Chung, So Ron Choi, Jeong Ho Kim, Sang Yoong Park
Korean J Anesthesiol. 2021;74(3):226-233.   Published online August 21, 2020
Background
Only a few studies have evaluated the differences between varying concentrations of a fixed dose of local anesthetics. This study was conducted to compare the effects of two different concentrations of a fixed dose of ropivacaine used in ultrasound-guided interscalene brachial plexus block.
Methods
This prospective, randomized, double-blind study included 62 patients who underwent arthroscopic surgery under general anesthesia. The patients were randomly assigned to receive ultrasound-guided interscalene block with 75 mg of ropivacaine at one of two concentrations: 0.75% (10 ml; group C) or 0.375% (20 ml; group V). Time to onset of sensory blockade, degree of blockade, pulmonary function changes, analgesic duration of the interscalene block, postoperative opioid requirement within 24 h, postoperative pain scores, satisfaction, and incidence of complications were recorded.
Results
Although the time to onset of sensory blockade was shorter for group C (P = 0.015), successful blockade was achieved at 30 min after the interscalene block in both groups. The analgesic duration of the interscalene block was not significantly different between the groups. The amount of opioid used within 24 h after surgery was significantly reduced for group V compared with group C (P = 0.016). The rest of the parameters did not show any significant differences between the two groups.
Conclusion
Compared with 10 ml of 0.75% ropivacaine, interscalene block with 20 ml of 0.375% ropivacaine could be effective for the reduction of postoperative opioid requirement within 24 h after surgery despite it might not prolong the analgesic duration.
Endotracheal intubation in patients undergoing open abdominal surgery in the lateral position: a comparison between the intubating video stylet and fiberoptic intubating bronchoscopy
Amr Samir Wahdan, Nesrine Abdel rahman El-Refai, Sohaila Hussien Omar, Shady Amr Abdel Moneem, Mennatallah Magdi Mohamed, Mohamed Mahmoud Hussien
Korean J Anesthesiol. 2021;74(3):234-241.   Published online October 19, 2020
Background
Some situations compel anesthetists to execute endotracheal intubation in the lateral position. We compared elective endotracheal intubation in the lateral decubitus position using the video stylet (VS) device with the fiberoptic (FO) bronchoscope device in patients undergoing abdominal surgery.
Methods
Overall, 50 patients were enrolled in this prospective, randomized study. They were randomly classified into the VS intubation or FO intubating bronchoscope group. After anesthesia induction, patients were placed in the lateral decubitus position, and a single investigator well-versed with the use of the VS and FO bronchoscope performed the intubation. The primary outcome was the time taken for intubation. Secondary outcomes included the intubation success rate, hemodynamic response at specific time points and perioperative complications.
Results
The average time taken for intubation was significantly lesser in the VS group than in the FO group, with values of 39.5 ± 10.0 and 75.6 ± 16.2 s, respectively (P < 0.001). Incidences of a successful first attempt of intubation in the VS and FO groups were 88% and 100%, respectively, showing no significant difference. There was a negligible difference in complications between the groups, except sore throat, which showed a higher incidence in the VS group than in the FO group (P = 0.002).
Conclusions
In laterally positioned patients, elective endotracheal intubation with VS provides less intubation time; however, its use is accompanied by a significant increase in the hemodynamic response after intubation and an increased incidence of sore throat.
Preoperative high-sensitivity troponin I and B-type natriuretic peptide, alone and in combination, for risk stratification of mortality after liver transplantation
Young-Jin Moon, Hye-Mee Kwon, Kyeo-Woon Jung, Kyoung-Sun Kim, Won-Jung Shin, In-Gu Jun, Jun-Gol Song, Gyu-Sam Hwang
Korean J Anesthesiol. 2021;74(3):242-253.   Published online August 26, 2020
Background
Given the severe shortage of donor liver grafts, coupled with growing proportion of cardiovascular death after liver transplantation (LT), precise cardiovascular risk assessment is pivotal for selecting recipients who gain the greatest survival benefit from LT surgery. We aimed to determine the prognostic value of pre-LT combined measurement of B-type natriuretic peptide (BNP) and high-sensitivity troponin I (hsTnI) in predicting early post-LT mortality.
Methods
We retrospectively evaluated 2,490 consecutive adult LT patients between 2010 and 2018. Cut-off values of BNP and hsTnI for predicting post-LT 90-day mortality were calculated. According to the derived cut-off values of two cardiac biomarkers, alone and in combination, adjusted hazard ratios (aHR) of post-LT 90-day mortality were determined using multivariate Cox regression analysis.
Results
Mortality rate after 90 days was 2.9% (72/2,490). Rounded cut-off values for post-LT 90-day mortality were 400 pg/ml for BNP (aHR 2.02 [1.15, 3.52], P = 0.014) and 60 ng/L for hsTnI (aHR 2.65 [1.48, 4.74], P = 0.001), respectively. Among 273 patients with BNP ≥ 400 pg/ml, 50.9% of patients were further stratified into having hsTnI ≥ 60 ng/L. Combined use of pre-LT cardiac biomarkers predicted post-LT 90-day mortality rate; both non-elevated: 1.0% (21/2,084), either one is elevated: 9.0% (24/267), and both elevated: 19.4% (27/139, log-rank P < 0.001; aHR vs non-elevated 4.23 [1.98, 9.03], P < 0.001).
Conclusions
Concomitant elevation of both cardiac biomarkers posed significantly higher risk of 90-day mortality after LT. Pre-LT assessment cardiac strain and myocardial injury, represented by BNP and hsTnI values, would contribute to prioritization of LT candidates and help administer target therapies that could modify early mortality.
Experimental Research Article
Patient barrier acceptance during airway management among anesthesiologists: a simulation pilot study
Jill Querney, Javier Cubillos, Youshan Ding, Richard Cherry, Kevin Armstrong
Korean J Anesthesiol. 2021;74(3):254-261.   Published online December 7, 2020
Background
Protection of healthcare providers (HCP) has been a serious challenge in the management of patients during the coronavirus 2019 (COVID-19) pandemic. Additional physical barriers have been created to enhance personal protective equipment (PPE). In this study, user acceptability of two novel barriers was evaluated and the performance of airway management using PPE alone versus PPE plus the additional barrier were compared.
Methods
An open-label, double-armed simulation pilot study was conducted. Each participant performed bag-mask ventilation and endotracheal intubation using a GlideScope in two scenarios: 1) PPE donned, followed by 2) PPE donned plus the addition of either the isolation chamber (IC) or aerosol box (AB). Endotracheal intubation using videolaryngoscopy was timed. Participants completed pre- and post-simulation questionnaires.
Results
Twenty-nine participants from the Department of Anesthesia were included in the study. Pre- and post-simulation questionnaire responses supported the acceptance of additional barriers. There was no significant difference in intubating times across all groups (PPE vs. IC 95% CI, 26.3–35.1; PPE vs. AB 95% CI, 25.9–35.5; IC vs. AB 95% CI, 23.6–39.1). Comparison of post-simulation questionnaire responses between IC and AB showed no significant difference. Participants did not find the additional barriers negatively affected communication, visualization, or maneuverability.
Conclusions
Overall, the IC and AB were comparable, and there was no negative impact on performance under testing conditions. Our study suggests the positive acceptance of additional patient protection barriers by anesthesia providers during airway management.
Case Reports
Endotracheal intubation using a three-dimensional printed airway model in a patient with Pierre Robin sequence and a history of tracheostomy -a case report-
Seyeon Park, Jisoo Ahn, Hye-Jin Kim, Eun-Ji Choi, Hee Young Kim
Korean J Anesthesiol. 2021;74(3):262-265.   Published online September 15, 2020
Background
Pierre Robin sequence (PRS) patients have an increased risk of difficult intubation due to anatomical airway abnormalities, and intubation simulation with a three-dimensional (3D) printed airway model before anesthesia may facilitate safe airway management.
Case
We describe the case of a 6.5-year-old boy with a history of PRS (a triad of micrognathia, glossoptosis, and airway obstruction), tracheostomy, and subglottic fibrosis who required general anesthesia. Preparation for this potentially difficult intubation included estimation of endotracheal tube size using a 3D printed airway model derived from 3D computed tomography of the airway, which enabled successful endotracheal intubation via video laryngoscopy.
Conclusions
If general anesthesia is necessary in patients with dysmorphic features such as PRS and there is a history of tracheal pathology, the possibility of difficult intubation should always be considered and simulation of endotracheal intubation using a 3D printed model of the airway can be helpful clinically in such situations.
Refractory gram-negative septic shock complicated by extended purpura fulminans and multiple organ failure in a 23-year-old puerpera -a case report-
Dmitriy Viderman, Yerlan Umbetzhanov, Talgat Temirov, Vsevolod V Kuzkov
Korean J Anesthesiol. 2021;74(3):266-270.   Published online July 21, 2020
Background
Pregnancy-related infections are the third most common cause of maternal death worldwideThe aim of this report is to present a case of pregnancy-related infection, which progressed into refractory septic shock accompanied by purpura fulminans and multiple organ failure.
Case
A 23-year-old woman in the postpartum period developed fulminant, refractory septic shock complicated by purpura fulminans and multiple organ failure syndrome (acute respiratory distress syndrome, acute kidney injury, and encephalopathy). Management included antibacterial therapy, fluid and transfusion therapy, nutritional support, protective mechanical ventilation, hydrocortisone, a large dose of ascorbic acid, and thiamine. There were no neurological consequences and all organ functions returned to normal, although the predicted hospital mortality based on the Sequential Organ Failure Assessment (SOFA) score was more than 90%.
Conclusions
Septic shock is a significant, yet not completely understood life-threatening condition, which can be associated with purpura fulminans, multiple organ dysfunction, disseminated intravascular coagulation, and massive tissue necrosis.
Letters to the Editor
Local anesthetic systemic toxicity of levobupivacaine in erector spinae plane block
Shunsuke Yawata, Noritaka Imamachi, Shinichi Sakura, Hanako Yamamoto, Yoji Saito
Korean J Anesthesiol. 2021;74(3):271-272.   Published online October 26, 2020
Rescue intubation via i-gel® device in Pierre-Robin sequence
Ramón Eizaga Rebollar, Elena Borreiros Rodríguez, Ana Mercedes Martínez-Almendros Fernández, Paula Lozano Hierro, Luis Miguel Torres Morera
Korean J Anesthesiol. 2021;74(3):273-275.   Published online October 19, 2020
Point-of-care ultrasonography as rescue for popliteal artery cannulation in prone position
Chitta Ranjan Mohanty, Snigdha Bellapukonda, Nitish Topono, Satyaki Sarkar, Priyank Tapuria
Korean J Anesthesiol. 2021;74(3):276-277.   Published online October 30, 2020
Comment on "A rare case of Wilson disease associated with intracerebral hemorrhage"
Shweta A Singh
Korean J Anesthesiol. 2021;74(3):278-279.   Published online October 19, 2020
Response to comment on “A rare case of Wilson disease associated with intracerebral hemorrhage”
Shalendra Singh, Priya Taank
Korean J Anesthesiol. 2021;74(3):280-281.   Published online October 19, 2020


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists
Business Registration: 106-82-07194
Representative: Young-Tae Jeon

Copyright © 2026 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next