Special Issue: Airway Management
Supraglottic airway devices: more good than bad
Hee-Pyoung Park
Korean J Anesthesiol. 2019;72(6):525-526.   Published online November 29, 2019
Review Articles
High-flow nasal oxygenation for anesthetic management
Hyun Joo Kim, Takashi Asai
Korean J Anesthesiol. 2019;72(6):527-547.   Published online June 5, 2019
High-flow nasal oxygenation (HFNO) is a promising new technique for anesthesiologists. The use of HFNO during the induction of anesthesia and during upper airway surgeries has been initiated, and its applications have been rapidly growing ever since. The advantages of this technique include its easy set-up, high tolerability, and its abilities to produce positive airway pressure and a high fraction of inspired oxygen and to influence the clearance of carbon dioxide to some extent. HFNO, via a nasal cannula, can provide oxygen both to patients who can breathe spontaneously and to those who are apneic; further, this technique does not interfere with bag-mask ventilation, attempts at laryngoscopy for tracheal intubation, and surgical procedures conducted in the airway. In this review, we describe the techniques associated with HFNO and the advantages and disadvantages of HFNO based on the current state of knowledge.
Awake supraglottic airway guided flexible bronchoscopic intubation in patients with anticipated difficult airways: a case series and narrative review
Wan Yen Lim, Patrick Wong
Korean J Anesthesiol. 2019;72(6):548-557.   Published online September 2, 2019
Awake intubation is indicated in difficult airways if attempts at securing the airway after induction of general anesthesia may lead to harm due to potential difficulties or failure in those attempts. Conventional awake flexible bronchoscopic intubation is performed via the nasal, or less commonly, oral route. Awake oral flexible bronchoscopic intubation (FBI) via a supraglottic airway device (SAD) is a less common technique; we refer to this as ‘supraglottic airway guided’ FBI (SAGFBI). We describe ten cases with anticipated difficult airways in which awake SAGFBI was performed. After sedation and adequate airway topicalization, an Ambu AuragainTM SAD was inserted. A flexible bronchoscope, preloaded with a tracheal tube, was then inserted through the SAD. Finally, the tracheal tube was railroaded over the bronchoscope, through the SAD and into the trachea. The bronchoscope and the SAD were carefully removed, whilst keeping the tracheal tube in-situ. The technique was successful and well tolerated by all patients, and associated complications were rare. It also offered the advantages of performing an ‘awake test insertion’ of the SAD, an ‘awake look’ at the periglottic region, and an ‘awake test ventilation.’ In certain patients, awake SAGFBI offers advantages over conventional awake FBI or awake videolaryngoscopy. More research is required to evaluate its success and failure rates, and identify associated complications. Its place in difficult airway algorithms may then be further established.
Statistical Round
Other Issue
Multicollinearity and misleading statistical results
Jong Hae Kim
Korean J Anesthesiol. 2019;72(6):558-569.   Published online July 15, 2019
Multicollinearity represents a high degree of linear intercorrelation between explanatory variables in a multiple regression model and leads to incorrect results of regression analyses. Diagnostic tools of multicollinearity include the variance inflation factor (VIF), condition index and condition number, and variance decomposition proportion (VDP). The multicollinearity can be expressed by the coefficient of determination (Rh2) of a multiple regression model with one explanatory variable (Xh) as the model’s response variable and the others (Xi [i ≠ h]) as its explanatory variables. The variance (σh2) of the regression coefficients constituting the final regression model are proportional to the VIF (11-Rh2). Hence, an increase in Rh2 (strong multicollinearity) increases σh2. The larger σh2 produces unreliable probability values and confidence intervals of the regression coefficients. The square root of the ratio of the maximum eigenvalue to each eigenvalue from the correlation matrix of standardized explanatory variables is referred to as the condition index. The condition number is the maximum condition index. Multicollinearity is present when the VIF is higher than 5 to 10 or the condition indices are higher than 10 to 30. However, they cannot indicate multicollinear explanatory variables. VDPs obtained from the eigenvectors can identify the multicollinear variables by showing the extent of the inflation of σh2 according to each condition index. When two or more VDPs, which correspond to a common condition index higher than 10 to 30, are higher than 0.8 to 0.9, their associated explanatory variables are multicollinear. Excluding multicollinear explanatory variables leads to statistically stable multiple regression models.
Clinical Research Articles
Special Issue: Airway Management
Comparison of Air-QⓇ insertion techniques in pediatric patients with fiber-optic bronchoscopic assessment: a prospective randomized control trial
Manasa Gaddam, Sameer Sethi, Aditi Jain, Vikas Saini
Korean J Anesthesiol. 2019;72(6):570-575.   Published online June 4, 2019
Background
Air-Q? laryngeal mask airway (LMA) is a second-generation supraglottic airway device (SAD) providing adequate airway control despite the unfavorable airway anatomy in children. Several studies have assessed it as a conduit for tracheal intubation and compared its efficacy with that of other SADs, but there are no studies comparing the laryngeal view with midline and rotational insertion techniques of Air-Q. Therefore, this study compared the fiber-optic bronchoscopic (FOB) assessment of the Air-Q position using these two insertion techniques.
Methods
This randomized controlled trial included 80 patients of the American Society of Anesthesiologists physical status I/II of either sex (age group 5?12 years, weight 10?30 kg), who were scheduled for elective surgery in the supine position under general anesthesia. The patients were randomly subjected to rotational and midline technique groups (n = 40, each), and appropriate sized Air-Q, based on the weight of the patient, was inserted using the technique allocated to each patient. Time taken and number of attempts for successful insertion of the devices and any complications after removal of device were studied.
Results
FOB grade 1 (ideal position) was seen in 29/40 (72.5%) and 19/40 (47.5%) children subjected to the rotational and classic midline techniques, respectively (P = 0.045). The time taken to successfully insert the Air-Q was significantly lesser in the rotational technique group (7.2 ± 1.5 s) than in the classic midline technique group (10.2 ± 2.1 s) (P < 0.001), whereas complications were similar in both groups.
Conclusions
The rotational technique was associated with better FOB view, and was faster than the classic midline technique of Air-Q insertion in pediatric patients.
Comparison of clinical performance of i-gelⓇ and Baska MaskⓇ during laparoscopic cholecystectomy
So Ron Choi, Tae Young Lee, Sung Wan Kim, Sang Yoong Park, Chan Jong Chung, Jeong Ho Kim
Korean J Anesthesiol. 2019;72(6):576-582.   Published online August 20, 2019
Background
The supraglottic airway device is an appropriate alternative to tracheal intubation in laparoscopic surgery. We compared the Baska Mask? with i-gel? by measuring the oropharyngeal leak pressure (OLP) and hemodynamic and respiratory parameters during laparoscopic cholecystectomy.
Methods
A total of 97 patients were randomly allocated to either i-gel group (n = 49) or Baska Mask group (n = 48). Insertion time, number of insertion attempts, fiber-optic view of the glottis, and OLP were recorded. Heart rate, mean arterial pressure, peak airway pressure (PAP), lung compliance, and perioperative complications were assessed before, during, and after pneumoperitoneum.
Results
There were no significant differences between the two groups regarding demographic data, insertion time, fiber-optic view of the glottis, and the use of airway manipulation. The OLP was higher in the Baska Mask group than in the i-gel group (29.6 ± 6.8 cmH2O and 26.7 ± 4.5 cmH2O, respectively; P = 0.014). Heart rate, mean arterial pressure, PAP, and lung compliance were not significantly different between the groups. The incidence of perioperative complications was small and not statistically significant.
Conclusions
Both the i-gel and Baska Mask provided a satisfactory airway during laparoscopic cholecystectomy. Compared with the i-gel, the Baska Mask demonstrated a higher OLP.
Effects of propofol, desflurane, and sevoflurane on respiratory functions following endoscopic endonasal transsphenoidal pituitary surgery: a prospective randomized study
Abdulvahap Oguz, Eren Fatma Akcil, Yusuf Tunali, Hayriye Vehid, Ozlem Korkmaz Dilmen
Korean J Anesthesiol. 2019;72(6):583-591.   Published online October 11, 2019
Background
General anesthesia with intravenous or inhalation anesthetics reduces respiratory functions. We investigated the effects of propofol, desflurane, and sevoflurane on postoperative respiratory function tests.
Methods
This single-center randomized controlled study was performed in a university hospital from October 2015 to February 2017. Ninety patients scheduled for endoscopic endonasal transsphenoidal pituitary surgery were randomly categorized into either of these three groups: propofol (n = 30, the Group TIVA), desflurane (n = 30, the Group D) or sevoflurane (n = 30, the Group S). We analyzed the patients before, after, and 24 h following surgery, to identify the following parameters: forced expiratory volume in 1 second (FEV1) %, forced vital capacity (FVC) %, FEV1/FVC, and arterial blood gases (ABG). Furthermore, we also recorded the intraoperative dynamic lung compliance and airway resistance values.
Results
We did not find any significant differences in FEV1 values (primary outcome) among the groups (P = 0.336). There was a remarkable reduction in the FEV1 and FVC values in all groups postoperatively relative to the baseline (P < 0.001). The FVC, FEV1/FVC, ABG analysis, compliance, and airway resistance were similar among the groups. Intraoperative dynamic compliance values were lower at the 1st and 2nd hours than those immediately after intubation (P < 0.001).
Conclusions
We demonstrated that propofol, desflurane, and sevoflurane reduced FEV1 and FVC values postoperatively, without any significant differences among the drugs.
Other Issue
Other Issue
Validity of bispectral index monitoring during deep sedation in children with spastic cerebral palsy undergoing injection of botulinum toxin
Sung Mee Jung, Eunhee Lee, Sang-Jin Park
Korean J Anesthesiol. 2019;72(6):592-598.   Published online August 3, 2019
Background
This prospective study aimed to determine whether the bispectral index (BIS) is a valid objective tool for differentiating adequate from inadequate deep sedation in spontaneously breathing children with cerebral palsy (CP).
Methods
Propofol was titrated to increase the level of sedation with a continuous infusion of remifentanil at a rate of 0.05 μg/kg/min while maintaining spontaneous ventilation in 22 children with spastic CP, aged 3?18 years. The depth of sedation was assessed using the University of Michigan Sedation Scale (UMSS) and the Modified Observer’s Assessment of Alertness and Sedation (MOAAS) scale. Receiver operating characteristic curve analysis was performed to determine the cutoff BIS values for deep sedation, defined as a UMSS score of 3?4 and a MOAAS score of 0?1.
Results
The BIS values significantly changed with the increase in the level of sedation across both the UMSS and MOAAS scores (P < 0.001). The BIS values correlated with the UMSS (r = ?0.795, P < 0.001) and MOAAS (r = 0.815, P < 0.001) scores. The cutoff BIS value to detect adequate deep sedation in children with CP was 61.5 (UMSS score: sensitivity 0.860, specificity 0.814; MOAAS score: sensitivity 0.794, specificity 0.811).
Conclusions
The BIS value strongly correlates with the clinical sedation scales, such as the UMSS and MOAAS, during deep sedation in children with CP. Therefore, BIS monitoring can be used as a valid tool for assessing the level of propofol sedation in spontaneously breathing children with CP undergoing a botulinum toxin injection.
Prediction of early postoperative desaturation in extreme older patients after spinal anesthesia for femur fracture surgery: a retrospective analysis
Youn Yi Jo, Chun Gon Park, Ji Yeon Lee, Sun Koo Kwon, Hyun Jeong Kwak
Korean J Anesthesiol. 2019;72(6):599-605.   Published online August 3, 2019
Background
Postoperative desaturation in older individuals is rarely addressed in the literature. The objective of this retrospective study was to investigate whether a preoperative spirometric test and arterial blood gas analysis (ABGA) might predict postoperative desaturation after spinal anesthesia in extreme older patients.
Methods
The medical records of 399 patients (age ≥ 80 yrs) who were administered spinal anesthesia for a femur neck fracture surgery were retrospectively reviewed. Early postoperative desaturation was defined as a reduction of oxygen saturation (SpO2) below 90% within 3 days of surgery, despite O2 supply via a nasal prong. Binary logistic regression analysis was used to identify predictors of early postoperative desaturation.
Results
The incidence of postoperative desaturation was 12.5%. Major morbidity rate was significantly higher in the desaturation group (n = 50) than that in the non-desaturation group (n = 349) (14% vs. 3.2%, P = 0.001) with more frequent postoperative stays in the intensive care unit (22% vs. 12%, P = 0.004). In a binary logistic regression analysis, preoperative ratio of arterial oxygen partial pressure to fractional inspired oxygen (PaO2/FiO2 ratio) (OR, 0.972; 95% CI 0.952?0.993; P = 0.010) and history of cardiovascular disease (OR, 2.127; 95% CI 1.004?4.507; P = 0.049) predicted postoperative desaturation.
Conclusions
Preoperative PaO2/FiO2 ratio, but not preoperative spirometry, was predictive of the postoperative desaturation in older patients after being administered spinal anesthesia for femur fracture surgery. Based on our results, preoperative ABGA may be helpful in predicting early postoperative desaturation in these patients.
Case Reports
Special Issue: Airway Management
Unilateral hypoglossal nerve palsy after the use of laryngeal mask airway (LMA) Protector
Li Yeen Tham, Zhi Yuen Beh, Ina Ismiarti Shariffuddin, Chew Yin Wang
Korean J Anesthesiol. 2019;72(6):606-609.   Published online July 15, 2019
Background
The laryngeal mask airway (LMA?) ProtectorTM (Teleflex Medical Co., Ireland) is the latest innovation in the second generation of LMA devices. One distinguishing feature of this device is its integrated, color-coded cuff pressure indicator (Cuff PilotTM technology) which enables continuous cuff pressure monitoring and allows adjustments when necessary; this ensures patient safety due to better monitoring.
Case
We report a case of postoperative unilateral hypoglossal nerve palsy after uncomplicated use of the LMA Protector. To the best of our knowledge, this could be the second reported case.
Conclusions
This case demonstrates that anesthetists need to routinely measure cuff pressure and that the Cuff PilotTM technology is not a panacea for potential cranial nerve injury after airway manipulation.
Postoperative use of high flow nasal insufflation for obstructive sleep apnea
Avinash Gobindram, Prit Anand Singh, Kelvin Howyow Quek
Korean J Anesthesiol. 2019;72(6):610-613.   Published online July 15, 2019
Background
Continuous positive airway pressure (CPAP) therapy is the gold standard treatment for obstructive sleep apnea (OSA), although, associated with poor patient compliance. Conversely, high flow, humidified, temperature-regulated nasal insufflation of oxygen or air is well tolerated.
Case
We describe our experience of three patients with known or suspected moderate to severe OSA who were poorly compliant to CPAP therapy and received high flow nasal insufflation (HFNI) postoperatively. None had significant episodes of desaturation (SpO2 < 95%) and all patients uniformly reported superior comfort levels than with the CPAP therapy. HFNI generates small amounts of positive end-expiratory pharyngeal pressure, increases inspiratory airflow and decreases dead space ventilation. Due to the open system, less difficulty with the patient-mask interface and improved patient comfort is experienced. These factors help prevent hypopnea and lead to enhanced sleep continuity.
Conclusions
HFNI may be a promising alternative to CPAP therapy in the perioperative setting.
Letters to the Editor
Ambiguous pediatric endotracheal tube intubation depth markings: a need for standardization
Neha Singh, Chitta Ranjan Mohanty, Parnandi Bhaskar Rao
Korean J Anesthesiol. 2019;72(6):614-615.   Published online February 19, 2019
Use of LMAⓇ GastroTM in esophagogastroduodenoscopy and endoscopy
Wan-Ling Alyssa Chiew, Qingyan Chen, Leng Zoo Tan
Korean J Anesthesiol. 2019;72(6):618-619.   Published online July 1, 2019
A case of fiberoptic bronchoscopy used as innovative aid for life saving in difficult surgical tracheostomy patient
Nitasha Mishra, Shalendra Singh
Korean J Anesthesiol. 2019;72(6):620-621.   Published online July 1, 2019
Postoperative high-flow nasal insufflation for obstructive sleep apnea: a potential therapeutic alternative or prudence needed?
Montserrat Diaz-Abad, Paschalis Steiropoulos, Antonio M Esquinas
Korean J Anesthesiol. 2019;72(6):622-623.   Published online August 20, 2019
Corrigendum
Other Issue
Corrigendum: Fluid responsiveness in the pediatric population
Ji-Hyun Lee, Eun-Hee Kim, Young-Eun Jang, Hee-Soo Kim, Jin-Tae Kim
Korean J Anesthesiol. 2019;72(6):624-624.   Published online November 29, 2019


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists
Business Registration: 106-82-07194
Representative: Young-Tae Jeon

Copyright © 2026 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next