Korean J Anesthesiol Search

CLOSE


Previous issues

  • HOME
  • BROWSE ARTICLES
  • Previous issue
Volume 41(3); Sep 2001
Clinical Research Articles
Adequate Dosage for Midazolam Premedication in Koreans.
Jin Deok Joo, Dae Woo Kim, Jang Hyeok In
Korean J Anesthesiol. 2001;41(3):269-274.
BACKGROUND
Midazolam is often used as an anxiolytic premedication before surgery. Although the sedative, anxiolytic, and amnestic properties of midazolam may be desirable before the induction of general anesthesia, respiratory function is impaired frequently by larger doses of midazolam. Therefore, we evaluated the adequate doses of midazolam premedication on anxiolytic and sedation without its serious side effects.
METHODS
Eighty ASA I or II adult patients scheduled for elective minor surgery were randomly allocated to four groups according to premedication doses of midazolam. They were group 1: midazolam 0.05 mg/kg IM for lean body mass (LBM); group 2: midazolam 0.075 mg/kg IM for LBM; group 3: midazolam 0.1 mg/kg IM for LBM.; group 4: midazolam 0.125 mg/kg IM for LBM. Blood pressure, heart rate, bispectral index (BIS), oxygen saturation (SpO2), anxiety visual analogue scale (VAS), and observer's assessment of alertness and sedation (OAA/S) scores were measured before and at 30 minutes after midazolam premedication. The frequency of apnea, defined as a cessation of spontaneous respiration for more than 10 seconds, was recorded. Induction time and dose requirements in propofol-induced general anesthesia were recorded at the loss of opening their eyes on verbal command and eyelid reflex after starting the propofol infusion. Following intubation, blood pressure and heart rate were measured.
RESULTS
The bispectral index and anxiety VAS was significantly decreaced in group 3 and group 4. However, oxygen saturation were significantly lower in group 4 compared with group 3.
CONCLUSIONS
We concluded that group 3 (midazolam 0.1 mg/kg IM for LBM) is the proper premedication dosage for anxiolytic and sedation in Koreans without respiratory side effects.
Is An Esophageal Doppler Monitor Useful in Hemodynamic Monitoring during a Laparoscopic Cholecystectomy?
Jae Yeoung Bae, Ji Eun Kim, Hee Cheol Jin, Wook Park
Korean J Anesthesiol. ;41(3):275-279.
BACKGROUND
To measure hemodynamic changes during a laparoscopic cholecystectomy (LC), we used a new, noninvasive esophageal doppler monitor (EDM).
METHODS
Under general anesthesia, 17 patients undergoing a LC were prepared by inserting an EDM probe into the esophagus. Cardiac index (CI), corrected flow time (FTc), systemic vascular resistance (SVR), mean arterial pressure (MAP), and heart rate (HR) were measured 6 times-before pneumoperitoneum, 5 minutes after pneumoperitoneum, 5, 15, and 30 minutes after the reverse trendelenberg position and after exsufflation of CO2 gas. Complication and insertion time of the EDM were also recorded. Data was analyzed using a repeated measure ANOVA.
RESULTS
CO2 gas insufflation resulted in an abrupt increase of SVR (51%), MAP (17%) and a decrease of CI (29%), FTc (13%). These changes were gradually restored, except the MAP. HR was not changed significantly. These findings correlated well with other studies using a thermodilution technique or transesophageal echocardiography. There was no complication with the EDM and insertion time was 182 32.3 sec.
CONCLUSIONS
Since MAP and HR do not offer accurate hemodynamic information during pneumoperitoneum, other adequate cardiovascular monitors are required. An EDM can be used during LC because it provides CI and FTc by a simple and noninvasive method.
The Effect of Inhaled Desflurane Concentrations on the Bispectral Index.
Ho Yeong Kil, Seong Jun Hong, Bong Soo Chae, Hoon Park, Tae Hyun Han, Hyun Hwa Lee
Korean J Anesthesiol. 2001;41(3):280-283.
BACKGROUND
The bispectral index (BIS) has been designed to objectively measure the degree of sedation and hypnosis for several anesthetics. The aim of this study was to evaluate the changes of the BIS during desflurane-N2O-O2 anesthesia.
METHODS
With Institutional Review Board approval and informed consent, forty premedicated (atropine 0.5 mg, IM) male and female adult patients (ASA class 1 or 2, 18 55 yrs) scheduled for elective surgery were studied. After intubation with the aid of propofol (2.0 mg/kg) and vecuronium (0.15 mg/kg), anesthesia was maintained with desflurane in combination with 50% N2O and 50% O2. Several transitions between 3.0 and 12.0 vol% were performed. During anesthesia, the BIS was checked at least 30 min after induction to avoid the residual effect of propofol and after 15 min maintenance of a certain inhaled concentration for equilibration.
RESULTS
The values of BIS were correlated closely with the desflurane concentrations (r = 0.88). Steep changes in the BIS were shown between 1.5 6.0 vol% and a ceiling effect regarding the BIS over 6.0 vol% was observed.
CONCLUSIONS
The BIS is valuable for measuring the degree of sedaton and hypnosis in desflurane anesthesia. Above 6.0 vol%, desflurane showed a ceiling effect regarding the BIS.
Effect of Midazolam, Fentanyl and Propofol for Intravenous Anesthesia in Patients Undergoing the Cardioversion.
Mee Young Chung, Jun Seuk Chea, Chang Jae Kim, Hee Yeol Kim, Eun Ju Cho, Hee Sang Park, Byung Ho Lee
Korean J Anesthesiol. 2001;41(3):284-288.
BACKGROUND
Elective cardioversion is a short procedure performed under amnesia, sedation or anesthesia for the treatment of cardiac dysrhythmia. Midazolam, fentanyl and propofol on hemodynamic changes and side effects were studied.
METHODS
Thirty patients scheduled for an elective cardioversion in the coronary care unit received propofol 500microgram/kg I.V., followed by a continuous infusion with 25 75microgram/kg/min until they lost consciousness as determined by cessation of response to verbal command. All patients received midazolam 0.02 mg/kg and fentanyl 2microgram/kg I.V. 5 minutes before induction. In addition, the cardiologist administrated the electric shock. Blood pressures and heart rates were measured prior to induction, after the administration of midazolam and fentanyl, after cardioversion, 5 minutes after cardioversion and recovery. The recovery time from terminating drug administration to awakening, and the total dose of propofol were recorded. Patients were observed for side effects.
RESULTS
Systolic, mean, and diastolic blood pressures were significantly decreased 5 minutes after cardioversion and recovery. Heart rates were significantly decreased after cardioversion, 5 minutes after cardioversion and recovery. Recovery times were 22.1 14.9 minutes and the total dose of propofol was 0.79 0.39 mg/kg. Incidence of apnea (> 30 s) was 30%.
CONCLUSIONS
We concluded that midazolam, fentanyl and propofol in patients undergoing an electric cardioversion decreased blood pressure and heart rate, but the cardiovascular status was maintained within clinically acceptable levels.
Comparison between the Flexiblade Laryngoscope and the Macintosh Blade Laryngoscope in Endotracheal Intubation.
Sun Young Jang, Sang Kyi Lee, Jun Rae Lee
Korean J Anesthesiol. 2001;41(3):289-296.
BACKGROUND
The Flexiblade laryngoscope has a unique structure that is composed of a blade and a handle with a trigger. When the trigger of the Flexiblade laryngoscope is squeezed, the hyoepiglottic ligament is depressed, the epiglottis is moved anteriorly, and then the laryngoscopic grade is improved. This study was designed to compare the Flexiblade laryngoscope with the conventional Macintosh blade laryngoscope in the laryngoscopic view in endotracheal intubation.
METHODS
Following induction of general anesthesia, the laryngoscopic grades of 110 patients were evaluated while five different blade positions of the Flexiblade laryngoscope and a laryngoscopy with the Macintosh blade were performed. The laryngoscopic grades which were described by Cormack and Lehane were classified from 1 to 4.
RESULTS
With the Macintosh blade laryngoscope, 98.2% of the patients were grade one and two, and 98.2% of the patients was laryngoscopic grade one and two with partial depression of the trigger of the Flexiblade laryngoscope. The laryngoscopic grade of maximal depression of the Flexiblade trigger had similar results to partial depression of the trigger. However, the partial depression of the Flexiblade laryngoscope showed better laryngoscopic views than the maximal depression of the Flexiblade laryngoscope or the Macintosh blade laryngoscope, respectively. In the overall success rate of endotracheal intubation and using the adjusting maneuvers, the Flexiblade laryngoscope was superior to the Macintosh blade laryngoscope.
CONCLUSIONS
The Flexiblade laryngoscope is comparable to the Macintosh blade laryngoscope for endotracheal intubation, therefore, the Flexiblade laryngoscope can be recommended as the first choice for endotracheal intubation.
Decrease in Oxygen Saturation with Pulse Oximetry Caused by Postintubation Croup in Pediatric Patients.
Young Ho Jang, Jin Mo Kim
Korean J Anesthesiol. 2001;41(3):297-301.
BACKGROUND
Postintubation croup (PC) is the rapid development of upper-airway obstruction as evidenced by hoarseness, stridor and/or chest retraction. This complication can lead to arterial desaturation and hypoxic bradycardia and these results may be serious, especially in pediatric patients. This study was undertaken to find the relationship between the oxygen desaturation and the duration of anesthesia. At the same time we tried to determine the incidence and etiologic factors of this complication.
METHODS
For this study, 400 children who received general anesthesia were studied. We investigated the several contributing factors in PC, such as age, anesthesia duration, and trauma during intubation. And the arterial oxygen saturation was measured by pulse oximetry.
RESULTS
The incidence of PC in children was 2 percent. Fifty percent of the patients with PC were 1 4 years old. There was no significant difference between sexes. 62.6% of the children received general anesthesia over 1 hour. There was no significance detected between the degree of oxygen desaturation and the anesthesia duration.
CONCLUSIONS
We confirmed that the anesthesia duration (>1 hour) and age (1 4 years old) were important etiologic factors of PC. But the degree of oxygen desaturation was not correlated with the duration of anesthesia.
Comparative Study of Immunologic Parameters between Spinal and Epidural Anesthesia for a Cesarean Section.
Myung Hee Kim, Duck Hwan Choi, Yeong Lan Kang
Korean J Anesthesiol. 2001;41(3):302-310.
BACKGROUND
Surgical stress and anesthesia can cause postoperative immunosuppression. T helper lymphocytes play a central role in the immune response. Cytokines secreted from T helper type-1 (Th1) and Th2 influence patients' morbidity. The purpose of the current study was to compare the effect of spinal anesthesia with epidural anesthesia on the T helper cell and cytokine secretions following cesarean section.
METHODS
Forty-four patients were randomly divided into two groups. Total lymphocytes, T helper cells, and T helper type-1 and type-2 cytokines, interleukin-2 (IL-2), interferon gamma (IFN-gamma), and IL-4 and IL-10 in the supernatant of CD4 cells stimulated with phytohemagglutinin were identified by using an enzyme-linked immune assay. Blood samples were obtained before surgery, 1, 3, and 24 h after the start of surgery.
RESULTS
Significant decreases in lymphocytes and CD4 cells at 3 and 24 h after the start of surgery were seen in epidural anesthesia. The Th1 response, IFN-gamma and IL-2 secretions were detected in 9 patients, in the spinal group, and 9 and 14 patients in the epidural group, respectively. There were no differences in the Th1 responses between the groups as well as within the groups. Th2 cytokine, IL-10 response in the higher concentration group receiving spinal anesthesia decreased significantly over the three time points studied, but decreased only at 24 h in the epidural group.
CONCLUSIONS
Our results show a possible different immune response profile between the spinal and epidural group: a decreased CD4 level in the epidural group and decreased IL-10 levels in the spinal group according to the time period after surgery.
Epidural Block with Prior Dural Puncture versus Combined Spinal Epidural Block for a Cesarean Section.
Hyoung Nam Kim, June Seog Choi, Chun Hee Park, Cheol Seung Lee, Won Tae Kim
Korean J Anesthesiol. 2001;41(3):311-317.
BACKGROUND
Epidural anesthesia became most popular for a cesarean section, but it is more time consuming and involves a higher incidence of insufficient or superficial blockade, especially of the motor root, despite large doses of local anesthesia. Combined spinal epidural anesthesia has gained an increasing interest as it combines the reliability of the spinal block and the flexibility of an epidural block. A dural puncture using the combined spinal epidural technique making an early sacral blockade might be a solution to disadvantages in epidural anesthesia. We investigated the efficacy of combined spinal epidural anesthesia and epidural anesthesia with prior dural puncture for a cesarean section.
METHODS
Sixty pregnant women at full term were divided into three groups. Group I (EPI, n = 20) received epidural anesthesia with 100 mg of 0.5% bupivacaine. Group II (CSE, n = 20) received combined spinal epidural anesthesia with 1.2 1.4 ml of 0.5% hyperbaric bupivacaine intrathecally, followed by sensory block at T10 after by 7 8 ml of 0.5% bupivacaine through the epidural catheter. Group III (DP, n = 20) received epidural anesthesia with prior dural puncture. A dural puncture with a 27 G whitacre needle was done before an infusion of 20 ml of 0.5% bupivacaine through the epidural catheter. The quality and side effects of surgical anesthesia were compared between the three groups.
RESULTS
Time to T10 (P< 0.001) and surgical onset time (P< 0.001) were significantly shorter in the CSE group. Maximal sensory block level (P< 0.001) was significantly higher in the CSE group. Muscle relaxation (P< 0.05) and motor block (P< 0.001) were much better in the CSE group. Hypotension occurred in 25% (EPI group), 40% (CSE group) and 20% (DP group) of the patients. While 65% of the EPI group and 50% of the DP group complained of intraoperative pain, only 25% of CSE group did (P< 0.05).
CONCLUSIONS
We can conclude that combined spinal epidural anesthesia has great efficacy and less side effects for a cesarean section than epidural anesthesia and epidural anesthesia with prior dural pucture.
The Effect of the IV-PCA (Intravenous-Patient Controlled Analgesia) on the Recovery Index.
Gwang Tae Cho, Ho Jung Sohn, Sang Bum Kim, Young Deok Shin, Jin Ho Bae, Sang Tae Kim, Seung Woon Lim
Korean J Anesthesiol. 2001;41(3):318-323.
BACKGROUND
It is well known that intravenous patient controlled analgesia (IV-PCA) is an effective method to reduce the magnitude of postoperative pain. However, we do not know the appropriate time to start the IV-PCA. To determine the appropriate time to minimalize the sympathetic stimulation and shorten the awakening time after general anesthesia, experiments to indicate whether starting an infusion of the IV-PCA before the end of an operation has a minimal hemodynamic change and similar recovery index compared with the control group were done.
METHODS
Seventy-eight patients scheduled for a total abdominal hysterectomy were randomly allocated to two groups. In the IV-PCA group (n = 37), we started the infusion of the IV-PCA before the end of the operation and in the control group (n = 41) which received no IV-PCA, we did not use the IV-PCA as a postoperative pain control method. We measured heart rate, blood pressure, postanesthesia recovery score every 10 minutes for 60 minutes and awakening time at the post-anesthesia care unit.
RESULTS
The postanesthesia recovery scores on arrival, 10, 20, 30, 40 and 50 minute after arrival at the post-anesthesia care unit were lower in the IV-PCA group than in the control group. In addition the awakening time after vaporizer-off and at the post-anesthesia care unit was longer in the IV-PCA group than in the control group.
CONCLUSIONS
We conclude that starting the infusion of the IV-PCA before the end of the operation is not effective in early recovery and awakening.
Effect of Epidural Morphine, Morphine with Droperidol and Morphine with Nalbuphine after a Cesarean Section.
Tong Il Kim, Hye Ja Kim, Jung Un Lee
Korean J Anesthesiol. 2001;41(3):324-330.
BACKGROUND
A number of recent reports have described the usefullness of the epidural injection of narcotics for the relief of postoperative pain. Morphine, an micro-receptor agonist, produces strong analgesic effects with side effects. Nalbupine, a micro-antagonist and kappa-agonis, has an analgesic effect comparable to morphine with little side effects. The comparison of side effects and analgesic effects of epidural morphine alone and a combination of nalbuphine and droperidol respectively to morphine were sutudied in cesarean section patients.
METHODS
We divided 45 patients into 3 groups utilizing a two-day Boxter infusor in normal saline 100 ml at 2.0 ml/hr: Group M (n = 15) initially a 1 mg bolus 2 mg/day of maintenance morphine. Group M D (n = 15): initially received a 1 mg bolus 2 mg/day of maintenance morphine 1.25 mg/day of maintenance droperidol. Group M N (n = 15): initially received a 1 mg morphine bolus 2 mg/day of maintenance morphine 5 mg/day of maintenance nalbupine. The Analgesic effect was evaluated by a visual analogue scale (0 10) at 30 min, 4 hr, 12 hr and 24 hr postoperatively and the incidence of side effects was observed too.
RESULTS
The average VAS scores are below 3 in all groups. In addition, there are no significant changes between groups. There are no significant differences in side effects between groups except sedation of patients is significantly (P< 0.05) high in group M D.
CONCLUSIONS
We concluded that the analgesic effect of epidural morphine, morphine with nalbuphine and morphine with droperidol are good in all patients and there is no significant difference even though there is a belief that a combination of nalbuphine or droperidol increases analgesic effects of morphine. Comparing the incidence of side effects in the three groups, the sedative effect of morphine with droperidol is increased significantly over the other two groups.intubation.
Experimental Research Articles
The Effect of Propofol (2,6-diisopropylphenol) and Thiopental Sodium on Fertilization and Early Embryo Development in Mouse IVF Model.
Hahck Soo Park, Sang Chul Lee, Kyung Nam Chung, Se Hwan Kim
Korean J Anesthesiol. 2001;41(3):331-336.
BACKGROUND
Propofol and thiopental sodium are short acting drugs and used as intravenous anesthetics for oocyte retrieval. Anesthetics administered during oocyte retrieval can pass into the follicular fluids and exert a detrimental effect on oocyte fertilizability. The aim of this study was to investigate the exposed concentration and time effect of these drugs on fertilization and early embryo development in a mouse in vitro fertilization (IVF) model.
METHODS
Mouse oocytes were exposed in vitro to propofol at 0 (control), 0.09, 0.45, 2.3, 4.5microgram/ml and thiopental sodium at 0 (control), 0.2, 1, 5, 10microgram/ml for 10, 30, 60 minutes, washed, and inseminated. Thereafter, fertilization was assessed. Subsequent in vitro development to the hatched embryo was monitored daily.
RESULTS
We found a concentration and time dependent toxic effect of propofol on the fertilizability of oocytes and early embryo development. The fertilization rate of mouse oocytes exposed for 30 minutes to medium containing 0.09microgram/ml of propofol was significantly lower than the control. The fertilization and hatching rate of mouse oocytes exposed for 10 minutes to medium containing 0.45microgram/ml of propofol was not lower than the control. We did not find a toxic effect of thiopental sodium on fertilization, but the hatching rate of fertilized oocytes exposed to medium containing thiopental sodium was significantly lower than the control.
CONCLUSIONS
We suggest that the oocyte retrieval procedure should be done as quickly as possible in order to limit the toxic effect of these anesthetics.
Effects of Propofol on the Cytosolic Calcium Concentration of the Astrocytoma Cells.
Young Soon Choi, Tong Mook Kang, Myung Hee Kim, Yong Keun Kwak, Huhn Choe, He Sun Song
Korean J Anesthesiol. 2001;41(3):337-346.
BACKGROUND
Propofol is a widely-used intravenous anesthetic with a rapid onset, short duration of action and rapid elimination but the molecular mechanisms of action are not completely understood. Not only neurons but astrocytes are potential substrates for anesthetics, specifically for propofol. Intracellular calcium ion ([Ca2 ]i) is known to play a key role in the transduction and propagation of various chemical signals in astrocytes.
METHODS
In the present study, the effects of propofol on the intracellular calcium concentration of astrocytoma cells by using a fura-2 fluorescence spectroscopy was investigated.
RESULTS
In an isotonic standard solution, propofol (50 and 500microM) produced a transient increase in [Ca2 ]i while the intralipid did not change [Ca2 ]i. In several cells (20%), a transient increase in [Ca2 ]i was followed by sustained elevation which was sensitive to depletion of external calcium. A propofol-induced increase in [Ca2 ]i was not altered by an L-type calcium channel blocker (nifedipine 2microM). In cells bathed in a Ca2 -free external solution, a transient increase in [Ca2 ]i was observed. After the pretreatment of cyclopiazonic acid (CPA), an endoplasmic reticulum Ca2 -ATPase blocker, propofol 500microM did not produce any significant increase in [Ca2 ]i. Carbachol, which is known to release calcium from the inositol 1,4,5-triphosphate (IP3)-induced calcium release (IICR) stores, prevented the [Ca2 ]i increase by propofol and vice versa. High concentrations of caffeine (10 mM), which release calcium from the calcium-induced calcium release (CICR) stores, had no effect on [Ca2 ]i.
CONCLUSIONS
From the above results, it is suggested that an increase in [Ca2 ]i by propofol in astrocytoma cells is mainly due to calcium release from the IICR stores.
Comparison of Antinociceptive Effect and c-Fos Expression of Pre- versus Posttreatment with Intrathecal Neostigmine on the Formalin Test.
Hye Weon Shin, Sang Ho Lim
Korean J Anesthesiol. 2001;41(3):347-357.
BACKGROUND
Intrathecal neostigmine produces antinociceptive effects in many pain tests. Comparisons of pre- versus postinjury drug interventions have been made using the formalin test as a model for central sensitization. The purpose of this study was to compare behavioral antinociceptive responses with spinal fos-like immunoreactivity (FLI) in an intrathecal neostigmine injection between pre- versus post-formalin administration in a rat pain model.
METHODS
Sprague-Dawley rats (250 300 g) were prepared with a PE 10 indwelling intrathecal catheter to receive either saline or neostigmine. The formalin test was performed on the second day after surgery with 5% 100microl. All rats were randomly divided into one of five groups; Sham, basal, control, pretreatment or posttreatment group. The Sham group (n = 4) received a dry needle at the hindpaw and the basal group (n = 6) received saline 100microl at the hindpaw. Saline 20microl was injected intrathecally after the formalin test in the control group (n = 8). Neostigmine (7.5microgram/10microl in volume) was administered intrathecally 7 minutes before the formalin test in the pretreatment group (n = 8) and 7 minutes after the formalin injection in the posttreatment group (n = 8). Pain related behavior was quantified by counting the incidence of flinches of the injected hindpaw for 60 minutes. Two hours after injection of formalin, animals were perfused with PBS and the spinal cords were removed immediately. The effect of pre- versus posttreatment with the neostigmine on c-Fos protein in the cord was examined by immunohistochemistry using specific antibodies. Immuno-positive cells in laminae I-II and III-V in the lumbar enlargement were calculated.
RESULTS
Intraplantar formalin injection produced a biphasic appearance of the flinch behavior (phase 1 = 0 5 minutes, phase 2 = 20 60 minutes) in the control, pretreatment and postreatment groups. In the pretreatment group, rats showed less remarkable phase 1 and 2 responses than other groups. Flinches of phase 1 were 2.3 2.1, 33.2 7.6 (P< 0.05 vs. basal), 10.0 6.6 and 33.0 13.4(P< 0.05 vs. basal) in basal, control, pre- and posttreatment groups respectively. Flinches of phase 2 were 0.3 0.5, 224.5 66.4 (P< 0.05 vs. basal), 120.6 151.3 and 187.5 76.8 (P< 0.05 vs. basal) in basal, control, pre- and posttreatment groups respectively. Similarly, the pretreatment group virtually inhibited formalin-induced expression of FLI (P< 0.05 vs. control, posttreatment) in the laminae I-II ipsilateral to injection. The posttreatment group inhibited formalin-indeced expression of FLI (P< 0.05 vs. control) in the laminae III-V ipsilateral to injection.
CONCLUSIONS
Pretreatment of intrathecal neostigmine inhibits nociceptive behaviors and FLI in the laminae I-II following formalin injection in rats, suggesting that pretreatment plays an important role in the development of plasticity in this model.
The Analgesic Effects of Intrathecal Clonidine on the Rat Postincisional Model.
Hong Bum Kim, Tae Sik Park, Sung Ho Lee
Korean J Anesthesiol. 2001;41(3):358-364.
BACKGROUND
Clonidine is an alpha2-adrenergic drug used for analgesic effect, reducing sympathetic stimulation and anesthetic requirement. We examined the analgesic effect of clonidine on incisional pain after its intrathecal administration using a rat postincisional model.
METHODS
After an intrathecal (IT) catheter insertion in 20 Spraw Dawley rats, they were divided into two groups; one group (Group S, n = 10) received a saline 20microl injection through an IT catheter, and another (Group C, n = 10) received clonidine 20microgram in 10microl volume followed by another 10microl of saline for washing the catheter. The measurements of the threshold of tactile allodynia (TTA) were performed at 20, 40, 60, 80, 120, 180 and 240 mins after the IT injection. Additionally, 1, 2 and 3 days after the first IT injection, IT injection and the measurements of TTA of pre- and post-injection were repeated. The measurements of TTA were performed in both areas, 5 mm (N-area) and 10 mm (R-area) away from incision by using von Frey hair and up-down method.
RESULTS
TTA (N-area) and TTA (R-area) during 4 hours after IT injection in Group C were greater than those in Group S (P< 0.05). TTA (N-area) of post-injection 2 and 3 days after the first IT injection were greater than those of pre-injection in Group C (P< 0.05), and TTA (R-area) after the IT injection 1, 2 and 3 days after the first IT injection were greater than those of pre-injection in Group C (P< 0.05).
CONCLUSIONS
A single IT injection of clonidine 20microgram had analgesic effects lasting more than 4 hours in the rat postincisional model. Additional IT clonidine could show antiallodynic effects during three days after the first IT clonidine.
The Comparative Effects of Dopamine and Dobutamine on Hemodynamics and Gastrointestinal Perfusion in Resuscitation of Hemorrhagic Shock.
Sung Jin Hong, Ji Young Lee, Jin Whan Choi, Yong Woo Choi, Se Ho Moon, Dong Suk Chung, Jong Bun Kim
Korean J Anesthesiol. 2001;41(3):365-378.
BACKGROUND
Preservation of intestinal perfusion is considered the goal of resuscitation because derangement of gut perfusion is the major factor in multi-organ dysfunction. Gut intramucosal pH measured by tonocap, has been proven to be the sensitive monitor of gut mucosal perfusion. The effects of vasoactive agents on regional blood flow and cellular metabolism remain unclear. This study was done to examine the effects of dopamine or dobutamine on systemic hemodynamics and splanchnic perfusion assessed by gastric intramucosal pH (pHi) during resuscitation of hemorrhagic shock.
METHODS
Thirty anesthetized dogs were bled to 30 40 mmHg of mean arterial pressure (MAP) and maintained at the shock state for 90 minutes. Cardiac output and arterial and mixed venous blood gas data was measured for the global assessment of circulation and oxygenation. Gastric intramucosal pH (pHi) and CO2 tension (PrCO2) and the difference of arterial and gastric intramucosal CO2 tension (CO2 gap) were measured for the assessment of splanchnic perfusion. Dogs were resuscitated with shed blood and a crystalloid solution at the maintenance dose (control group, n = 10). Dopamine (4microgram/kg/min, dopamine group, n = 10) or dobutamine (7microgram/kg/min, dobutamine group, n = 10 ) was added from the start of volume replacement and maintained for a follow-up period of 180 minutes.
RESULTS
Cardiac index and global oxygen delivery and consumption were increased after resuscitation in all groups. These parameters were significantly higher in the dopamine or the dobutamine groups than in the control group (P< 0.05), and significantly higher in the dopamine group than in the dobutamine group (P< 0.05). The pHi, PrCO2 and CO2 gap were not improved from the values of shock state after volume resuscitation in the control group. The pHi, PrCO2 and CO2 gap were significantly improved from the values of shock state after resuscitation in the dopamine group (P< 0.05), but not differentfrom the control group. The pHi, PrCO2 and the CO2 gap were significantly improved from the value of shock state after resuscitation in the dobutamine group and maintained significantly higher than in the control group for the follow-up period (P< 0.05). Compared to the dopamine group, the pHi increased early and was higher in the dobutamine group (P< 0.05).
CONCLUSIONS
We conclude that dobutamine is effective in improving gut mucosal oxygenation during early resuscitation of hemorrhagic shock. Dopamine has little effect on the restoration of gut mucosal oxygenation. Considering the better recovery of cardiac index and global oxygenation parameters in the dopamine group, this finding could be explained by the redistribution of cardiac output or imbalance of oxygen metabolism occuring in the dopamine group.
Case Reports
Caudal Anesthesia under Light Inhalational Anesthesia in a Premature Infant: A case report.
Seung Ok Hwang
Korean J Anesthesiol. 2001;41(3):379-382.
Premature infants are at high-risk of apnea after surgery. General anesthesia increases the risk of apnea. A 3-day-old male was scheduled for an anoplasty because of a low-type imperforated anus with a anoperineal fistula. The medical history was significant for premature birth at 345 weeks of gestation with a birth weight of 2,610 g. He had an irregular breathing pattern and self-limiting apnea. He also had bilateral 12th rib defect with substernal retraction. After an intravenous injection of ketamine 1 mg/kg and atropine 0.15 mg, a mask was positioned. A caudal block was performed via a 23 G angiocatheter using a single bolus dose of 0.8 ml/kg of 0.25% bupivacaine in the lateral position. He was immediately turned to a supine position and lithotomy position after slow injection of the drug. Anesthesia was maintained with isoflurane 0.2 0.6 vol.% in 50% O2 during preparation and operation under the masking. During 15 minutes of uneventful surgery, the infant remained comfortable but the breathing pattern was still irregular. No increase in the frequency of apnea was observed during the first postoperative day. A caudal block with light inhalational anesthesia was a successful method in a premature infant for anoplasty.
Vasovagal Syncope during a Caudal Epidural Block in a Patient with Vertebral Fractures: A case report.
Jun Hak Lee, Soo Jong Lee, Sang Cheol Park, Chae Sik Yun, Ki Nam Lee, Jun Il Moon
Korean J Anesthesiol. 2001;41(3):383-387.
Age-related vertebral fractures occur frequently in the elderly recently. An epidural block has been introduced as an effective management for the treatment of pain with vertebral compression fractures. While an epidural block is considered to be reasonably safe, serious complications may occur even when this invasive procedure is related to pain. Vasovagally mediated episodes of hypotension and bradycardia are thought to be a common cause of recurrent unexplained syncope. Precipitating factors include pain, trauma, fatigue, blood loss, or prolonged motionless standing. We report one case of vasovagal syncope associated with severe bradycardia and hypotension in a 78 year-old male patient with vertebral fractures. Syncopal attacks occurred during a caudal epidural block. The patient was resuscitated successfully and recovered without any adverse effects.
Anesthetic Management during Interventional Neuroradiologic Embolization of a Vein of Galen Malformation: A case report.
Kyu Seok Han, Sung Sik Park, Dong Gun Lim, Yong Sun Kim, Jung Gil Hong
Korean J Anesthesiol. 2001;41(3):388-392.
The vein of Galen malformation is a midline intracranial arteriovenous fistula with aneurysmal dilatation of the vein of Galen. This abnormality, though rare, is associated with a bleak prognosis and significant mortality. However, significant advancements have been made in understanding the pathophysiology of this abnormality, and improvements in both interventional neuroradiologic embolization and microneurosurgical techniques have contributed to a better outcome. In neuroradiologic embolization, children are likely to become agitated and confused and thereby jeopardize the entire procedure. For this reason, this procedure is performed with the children under general anesthesia. We experienced a case of neuroradiologic embolization under general anesthesia with propofol. The patient was a 9- year-old boy who weighed 29 kg. He was healthy and had no other abnormalities in our preoperative evaluation. Throughout the entire procedure, especially before and after closure of the fistula, hemodynamic changes and unexpected events did not appear.
High Frequency Oscillation Ventilation for Resection of Congenital Lobar Emphysema: A case report.
Hyun Jung Lee, Su Eun Park, Jae Young Kwon
Korean J Anesthesiol. 2001;41(3):393-397.
Congenital lobar emphysema (CLE) is a rare entity of unknown incidence. The main signs and symptoms are tachypnea, tachycardia, cyanosis, retractions, wheezing, tympanic chest percussion, asymetric breath sounds, or displaced cardiac tones within the first month of life. Occasionally a superimposed pulmonary infection exacerbates the condition, prompting hospital admission and medical treatment of the pneumonia followed by surgical treatment of the CLE. We now report a case of left upper CLE in a 15-day-old infant. Anesthesia was induced with thiopental sodium and maintained with intravenous fentanyl and midazolam. Endotracheal intubation was uneventful. Muscle relaxation was done with rocuronium. Gentle manual ventilation with a Mapleson D circuit was begun and changed to intermittent mandatory ventilation with an infant ventilator. During the left upper lobe resection, we used high frequency oscillation ventilation (HFOV) at FIO2 1.0, 12 Hz frequency, 12 cmH2O amplitude for 25 minutes. The minimal lung movement during HFOV was found to provide excellent operating conditions for the surgeons and adequate oxygenation without cardiovascular compromise. The PaCO2 was increased to 71 mmHg 25 minutes after the start of HFOV, and returned to normal value with intermittent mandatory ventilation. The remainder of the operation and anesthesia were uneventful. The patient was transferred to the neonatal intensive care unit.
Anesthetic Management for Clipping of a Ruptured Cerebral Aneurysm before Vaginal Delivery in a Term Parturient: A case report.
Hae Jin Lee, Yong Woo Choi
Korean J Anesthesiol. 2001;41(3):398-403.
A ruptured cerebral aneurysm in a term parturient requires a consideration of several factors important to the survival of both the mother and infant. A 39-week pregnant patient with a subarachnoid hemorrhage, secondary to a ruptured anterior communicating artery aneurysm, presented emergently for clipping of a cerebral aneurysm under general anesthesia. Anesthetic goals for this patient included maintenance of maternal well-being, uteroplacental perfusion, and fetal well-being. Fetal monitoring consisted of fetal heart rate by external Doppler and uterine activity by external tocodynamometer. The aneurysm was well clipped, and the patient was in a good neurological grade after surgery. A healthy baby was delivered 7 days postoperatively via the vaginal route under epidural analgesia. The anesthetic management of the case is described and discussed.


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists
Business Registration: 106-82-07194
Representative: Young-Tae Jeon

Copyright © 2026 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next