Korean J Anesthesiol Search

CLOSE


Previous issues

  • HOME
  • BROWSE ARTICLES
  • Previous issue
Volume 28(5); May 1995
Clinical Research Articles
Accuracy and Continuity of Infusion Devices with Volumetric Analyzer.
Jung Soo Yoon, Hwang Jung Kim, Jin Yun Kim, Sun Gyoo Park
Korean J Anesthesiol. 1995;28(5):611-617.
The proliferation of high-technology infusion devices has greatly influenced the practice of anesthesia by allowing precise delivery intraoperatively and postoperatively of intravenous anesthetics, analgesics, and vasopressors. During continuous drug administration to pediatric patients, unfavorable pharmacologic effects have occured. These effects were attributed to variations in flow from infusion devices. The intent of this investigation was to evaluate the influence of infusion devices on the accuracy and continuity effused fluid. Hartmann's solution was run through eight infusion pump at 5, 10, 15, 20, 25, 30, 40, 60, 80 and 100ml/hr. The volume of the fluid was measured for one hour at each flow rate using a infusion device analyzer(IDA-2) in vitro. Flow accuracy(ml/hr) was calculated by dividing the effused volume by the effusion time ; this value was subsequently expressed as a percentage of the desired flow rate. Flow continuity was expressed by the coefficient of variance(CV); analysis of variance with SAS was used for comparisons. Results were as follows ; 1) The flow accuracy values ranged from 98.8% to 114.2% of the desired rate. 2) Seven infusion pumps had flow rates within 5% of the desired rates at each flow rate but one pump had more than 10% of desired rate. 3) Each of the respective infusion pumps produced various levels of flow continuity and ranged from 0.7% to 2.5%(CV value). Conclusion , further evaluations are needed to differentiate continuity from other infusion devices(e.g., syringe infusion pump) in vitro and evaluations are needed to define the clinical significance in vivo. Future use of flow-rate data will likely be of significant value in establishing policies and procedures for the utilization of infusion devices and guidelines for product selection.
The Effects of Lidocaine and Clonidine Premedication on Cardiovascular Response during Induction of Anesthesia with Ketamine.
Hyun Wha Lee, Keon Sik Kim, Hwa Ja Kang, Young Kyoo Choi, Moo Il Kwon, Kwang Il Shin
Korean J Anesthesiol. 1995;28(5):618-625.
Ketamine may increase blood pressure and heart rate and should be avoided in hypertensive patients. However, in hypovolemic and asthmatic patients, ketamine is used as an induction agent because of its cardiovascular stimulating effect and bronchodilating effect. This study aims to assess the effects of clonidine and lidocaine on the cardiovascular response of intravenous ketamine administration during induction of anesthesia. sixty patients were divided into 3 groups as followed: group I: control ( received no lidocaine or no clonidine) group II: received lidocaine (1.5 mg/kg IV) 3 minutes before intubation group IIl: received clonidine (0.3 mg PO) 90 minutes before induction of anesthesia The changes of blood pressure, heart rate and rate pressure product following intubation were measured at different time interval (before induction,before intubation just after intubation, postintubation 1, 3, 5, 10 min) and compared with the value of control (2 hours before induction of anesthesia). The results are as follows 1) Group I and Group II: The systolic and diastolic blood pressure increased significantly compared to the control value from preinduction to 5 minutes after intubation(p<0.05). It recovered to the control value in 10 minutes, but heart rate and rate-pressure product increased significantly for 10 minutes after intubation(p<0.05) 2) Group III: The systolic and diastolic blood pressure, heart rate and rate-pressure product of preinduction and preintubation values decreased significantly compared to control values but 1 minute after intubation,all values increased significantly(p<0.05). The systolic and diastolic blood pressure and rate-pressure product values recovered to control value in 3 minutes after intubation and heart rate recovered in 5 minutes. Comparing group III with group I and II, it showed significant changes(p<0.05). From the above results, it can be concluded that clonidine inhibits cardiovascular stimulating response by ketamine during induction of anesthesia. the above results, it can be concluded that clonidine inhibits cardiovascular stimulating response by ketamine during induction of anesthesia.
Comparison of Thiopental Sodium and Propofol as to the Effects of Anesthesia Induction and Hemodynamic Changes to Endotracheal Intubation.
Myung Ha Yoon, Chan Jin Park, Young Sin Han
Korean J Anesthesiol. 1995;28(5):626-633.
The purpose of this study is to compare thiopental sodium and propofol as to the effects of anesthesia induction and hemodynamic changes associated with endotracheal intubation. Forty healthy adult patients, scheduled for elective surgery under general anesthesia, were randomly assigned to receive either thiopental sodium 5 mg/kg (Group 1, n =20) or propofol 2 mg/kg (Group 2, n=20) as an induction agent. Endotracheal intubation was performed following injection of succinylcholine 1 mg/kg. Anesthesia was maintained with 1.5~2% ethrane and 50% N2O in O2. The results were as follows, 1) Both thiopental sodium and propofol revealed high incidence of pain in the site of injection (13/20, 10/20, respectively). 2) The time from the start of injection to spontaneous closing of eyes and to loss of eyelid reflex were 42 and 43 sec in group 1 and 46 and 51 sec in group 2, respectively. 3) The loss of respiratory efforts. Occured in all cases and took 65 and 59 sec, in group 1 and 2 respectively. 4) The blood pressure was more decreased in group 2 than group 1 during induction period, but there was no significant difference between two groups. Also, there was no significant difference of the heart rate between two groups. 5) The increments of systolic blood pressure and rate-pressure-product to endotrachal intubation in group 2 were less than group 1 at time of immediate and 1 minute after intubation. Also, the increments of mean arterial pressure, disastolic blood presure and heart rate were lessen in group 2 than group 1. The retum of blood pressure, heart rate and RPP to the control was fasten in group 2 than group l. In conclusion, propofol may be an alternative to thiopental sodium in patients who require endotracheal intubation without hemodynamic instability.
The Effects of N2O on the Changes in the Cuff Pressure of the Laryngeal Mask Airway during General Inhalation Anesthesia.
Sang Kyi Lee, Jae Duk Yang, Dong Chan Kim, He Sun Song
Korean J Anesthesiol. 1995;28(5):634-639.
The laryngeal mask airway(LMA) is an alternative to tracheal intubation, especially in out-patient surgery or securing emergency airway. Several studies show that N2O diffuses into the cuffs of endotracheal tubes and increases the cuff pressures. Because LMA also has an air-filling cuff, the cuff pressure of LMA may be increased during general anesthesia with N2O. The purpose of this study was to evaluate the effects of LMA on the changes in the cuff pressure of the LMA during general inhalation anesthesia. In this study, we measured the cuff pressure of LMA after administration of 0%(group A), 50%6(group B), 60%(group C) or 66.7%o(group D) N2O with the air-inflated cuffs, and also measured the cuff pressure of LMA after administration of 66.7% N2O(group E) with the 66.7% N2O-inflated cuffs during general inhalation anesthesia. In group A, there was no significant cuff pressure change throughout the study period. In group B, C and D, the cuff pressures gradually increased as time elapsed and the more increased the concentration of N2O, the more increased the cuff pressures. In group E, the cuff pressure abruptly decreased until the first five minute, but recovered gradually and slightly increased than the baseline value for the rest of the measurement period. These findings demonstrate that N2O administration during general inhalation anesthesia significantly increases the cuff pressure of LMA in a concentration- and time-related fashion with the air-inflated cuffs but not with the N2O-inflated cuffs, and suggest that such increases may result in ischemia on cuff-related laryngeal area, and N2O-inflated cuffs may prevent increasing the cuff pressure of LMA.
Changes in Pulmonary Arterial Pressure and Pulmonary Vascular Resistance after Mitral Valve Replacement.
Jeong Seon Han, Yong Woo Hong, Sou Ouk Bang, Chung Hyun Park, Yun Young Choi, Young Seon Sou
Korean J Anesthesiol. 1995;28(5):640-647.
As the mitral valve disease becomes long-standing, the patient may develop pulmonary hypertension. It was reported that after surgical correction, the elevated pulmonary vascular resistance(PVR) would fall quickly in association with the fall in left atrial pressure(LAP). This study was performed to evaluate the changes in mean pulmonary artery pressure(PAP) and PVR immediately after mitral valve replacement(MVR). Fifty six patients undergoing mitral valve replacement(MVR) were divided into two groups on the basis of the presence or absence of significant pulmonary hypertension, defined as a resting mean pulmonary arterial pressure greater than 30mmHg. After induction of anesthesia, PAP, PVR, cardiac output(CO) were measured and compared with values in postbypass period. PAP and PVR were significantly decreased(PAP from 39.64+/-1.88 to 29.18+/-1.65 mmHg, P 0.001, PVR from 6.16+/-1.14 to 3.53+/-0.62 units, P<0.05) in Group II(PAP> or = 30mmHg, n=23), whereas not changed in Group I(PAP30 mmHg, n=33)(P<0.05). Persistance of an elevated PVR may cause right ventricular failure and low-output syndrome, so that an attempt to reduce the PVR is needed postoperatiavely. This study demonstrated that the PAP and PVR fall significantly after MVR especially in patients with severe pulmonary hypertension.
The Effects of Hypothermic Hemodilutional Cardiopulmonary Bypass on the Pseudocholinesterase Level .
Byung Kook Chae, Hye Won Lee, Seong Ho Chang
Korean J Anesthesiol. 1995;28(5):648-654.
Pseudocholinesterase is known to be involved in the metabolism of succinylcholine, mivacurium, procaine, chloroprocaine, tetracaine, cocaine, heroin, and other drugs, although the physiologic function has not been well established. Prolonged neuromuscular block following administration of succinylcholine correlates with very low or genetically variant cholinesterase activity. The determination of pseudocholinesterase activity is of importance to the anesthetist in order to predict the susceptibility of the patient to the muscle relaxant, succinylcholine. The purpose of this study was to investigate the change of pseudocholinesterase level during cardiopulmonary bypass(CPB) for open heart surgery with hemodilution and hypothermia. Seven venous blood samples before induction of anesthesia(control), during CPB, and until the fifth postoperative day in 12 patients who underwent open heart surgery were taken. The pseudocholinesterase level was measured by Wako kit and JASCO UVIDEC 77 clinical spectrophotometer. The results were as follows ; 1) The control hematocrit was 40.32+/-6.21% and decreased to 23.72+/-1.86% immediately after the start of CPB(p<0.01) and to 22.42+/-1.93 % 30 minutes after the start of CPB(p<0.01). 2) The control pseudocholinesterase value of 1296.67+/-251.03 IU/L decreased to 915.67+/-228.16 IU/L immediately after the start of CPB(p<0.01), and to 727.83+/-197.58 IU/L 30 minutes after the start of CPB(p<0.01). 3) The mean values of pseudocholinesterase level immediately posteratively, on the first postoperative, and the third postoperative days were 1488.50+/-333.52 IU/L, 1913. 17+614.50 IU/L and 1620.92+/-458.82 IU/L, respectively, and those were significantly increased from the control value(p<0.05, p<0.01, and p<0.01, respectively). 4) The mean value of pseudocholinesterase level on the fifth postoperative day was 1392.25+/-271.69 IU/L, which was not significantly different from the control valule. 5) Transfused units of whole blood, packed red cells, and fresh frozen plasma were 2.8+/-1.4, 3.2 +/-1.0, 3.4+/-0.9, respectively.
Experiences of Transesophageal echocardiography in Open Heart Surgery.
Hyun Soo Moon, Jeong Moo Seo, Mi Woon Kim, Sea Wook Sung
Korean J Anesthesiol. 1995;28(5):655-660.
Echocardiography has been the most widely applicable noninvasive cardiovascular imaging technique. Recent advances in this technique have extended its use into the operating room by development of transesophageal approach. Many anesthesiologists use transesophageal echocardiography (TEE) because it provides a more direct and rapid method of assessing cardiac anatomy and function. Intraoperative TEE done by anesthesiologists or cardiologists makes it possible for operation team to get useful informations such as cardiac filling, valvular function, cardiac contractility, intracardiac shunt, segmental wall motion abnormality and adequacy of coronary blood flow, etc. We analyzed our clinical experiences of forty six cases of TEE (6.0%) in 767 cases of anesthesia for open heart surgery at the Sejong General Hospital during the period from September 1993 to August 1994. 767 open heart surgical cases were divided into 4 groups by disease entity ; 498 cases of group I(congenital), 190 cases of group II(valvular), 63 cases of group III(ischemic) and 16 cases of group IV(miscellaneous). TEE was done for 22 cases of male patients and 24 cases of female patients. 32 cases of TEE were done for the age group between 21 to 30 years old. The number of TEE was 26 cases of group II, 11 cases of group I, 7 cases of group III and 2 cases of group IV, respectively. The main purpose of TEE in descending order was 27 cases for assessment of cardiac contractility, 18 cases for valvular function after valvuloplasty, 7 cases for the evaluation of low cardiac output syndrome(LCOS), and 7 cases for adequacy of coronary blood flow respectively. Two cases of Biopump in group I, 2 cases of Biopump in group II, 3 cases of intraaortic baloon pump(IABP) in group II, III and IV were applied after TEE. Two cases of mitral valvular replacement(MVR) were done immediately after confirmation of valvular insufficiency by TEE. These results have demonstrated that TEE is one of the useful monitoring devices for the anesthesia in open heart surgery by assessment of variable informations about patients' cardiac status.
The Effects of IV Solution during Cesarean Section on Umbilical Glucose, Electrolyte and Insulin.
Jung Goo Park, Jae Kyu Cheun, Ae Ra Kim
Korean J Anesthesiol. 1995;28(5):661-668.
It is well documented that rapid administration of solution containing dextrose results in marked hyperglycemia and osmotic diuresis. The maternal effect of hyperglycemia caused by rapid administration of dextrose solution may affect the fetus or the newborn baby as well. Therefore, there was a need to ascertain an appropriate IV solution for prehydration in cesarean section. The aim of this study was to determine an appropriate solution for cesarean section based on the results of the effects of matemal IV glucose solution on the newborn's glucose, electrolyte and insulin. 40 parturients scheduled for cesarem section were chosen at random. They were divided into two groups : one group received Hartmann's solution and the other group received 5% D/W. Patients' venous blood was drawn on the operating table prior to starting IV infusion for the measurement of blood sugar and electrolytes(Na, K, Cl) in various conditions of NPO. Then, intra-venous fluid was administered rapidly for prehydration about 20 ml/kg/hr(about 500 ml for 20 minutes) while anesthesia was induced and maintained with an endotracheal tube in place. The second blood samples were taken from matemal vein, umbilical vein and artery immediately after delivery for the measurement of glucose and electrolyte. At the same time insulin levels of umbilical veins were measured. The prehydrative glucose levels were 75.40+/-20.80 mg/dl in group 1 and 78.60+/-12.44 mg/dl in group 2. Both values were within normal range without significant hypoglycemia following the various times of NPO. Posthydration values of maternal glucose in group 2 with glucose infusion was 221.30+/-3.62 mg/dl. This was significantly higher than 72.20+/-7.11 mg/dl in group 1(p<0.05). At the time of delivery, the values of umbilical venous and arterial blood glucose in group 2 were significantly higher than in group 1(p<0.05). The values of insulin in umbilical venous blood in group 2 was 48.09+/-25.54 uU/ml. This was significantly higher than 6.06+/-2.06 uU/ml in group 1(p<0.05). Hydration using either solutions did not affect the value of electrolyte either in the mother or newborn baby. However, the rapid administration of glucose solution increased the maternal and umbilical glucoses as well as umbilical insulin proportionally. As the result of this study, prehydration with the solution containing glucose for cesarean section increased maternal and fetal glucoses as well as fetal insulin levels. Therefore, prehydration with any solution containing glucose is not recommended to prevent maternal and fetal hyperglycemia, and can result in delayed newbom hypoglycemia. It was concluded that prehydration with balanced electrolyte solution without dextrose seems to be safer to babies as well as mothers.
The Effect of Succinylcholine on the Action of Pipecuronium.
Sung Su Chung, Myung Ha Yoon, Woong Mo Im, Tae Suk Kim
Korean J Anesthesiol. 1995;28(5):669-675.
For the assessment the effect of succinylcholine (SCh) on pipecuronium, 52 adult patients undergoing elective surgery under general anesthesia were subjected to this study in which the EMG response (twitch height of the hand to TOF stimulation with 2Hz) of ulnar nerve was monitored and recorded with Datex Relaxograph. According to the amount and mode of the drugs administered, the patients were divided into four experimental groups: 1) Group I: a bolus injection of pipecuronium in dose of 0.05 mg/kg. 2) Group II: pipecuronium 0.1 mg/kg, a double dose of group l. 3) Group IU: pipecuronium 0.05 mg/kg given when the depressed twitch height by SCh (1 mg/kg) recovered to 25%6 of initial twitch height. 4) Group IV: mixed injection of SCh (1 mg/kg) and pipecumnium (0.05 mg/kg). The results were as follows ; 1) Mean onset time of pipecuronium was 6.5+/-0.5 minutes in group I and 4.1+/-0.5 minutes in group II, the latter being significantly shorter than group I (p<0.01). In group Ill, it was 2.1+/-0.23 minutes being significantly shorter than group I, II (p<0.001). In group IV it was 1.1+/-0.1 minutes which was more significantly shorter than group I, II, and IU. 2) Mean action duration of pipecuronium was 50.9+/-6.7 minutes in group I and 141.9+/-15.4 minutes in group II, the latter being longer significantly (p<0.001). In group IIl, it was 53.9+/-5.2 minutes which was similar to group I, but it was 69.8+/-6.5 minutes in group IV, being significantly longer than those of group I and III (p<0.05). 3) Mean potency of pipecuronium expressed by the percentage change of initial twitch height was 7.6+/-1.9% in group I, but it was significantly decreased to 4.2+/-0.9% in group II (p<0.05). In group III, it was 0.2+/-0.1% being sinificantly decreased than group I, II (p<0.001). In group IV, it was 0.0+0.0% being more significantly decreased than other groups (p<0.001). 4) Presence of pipecuronium in group IV did not affect on the intensity of fasciculation induced by SCh. These results indicate that succinylcholine may potentiate the pipecuronium based on the findings that succinylcholine increased the potency and lengthened the duration of action of pipecuronium.
Assessment of the Optimal Interval of Tetanic Stimulation for Post-Tetanic Count.
Jeong Uk Han, Kyo Sang Kim
Korean J Anesthesiol. 1995;28(5):676-681.
Post-tetanic count(PTC) was a known monitoring method to evaluate intense neuromuscular blockade of peripheral muscles. It has been reported that intermittent tetanic stimulation(50 Hz for 5 sec.) every 6 to 10 min. during intense nondepolarizing neuromuscular blockade did not influence the recovery of neuromuscular transmission. However, the relatively frequent use of tetanic stimulation might be possible to influence the recovery of neuromuscular blockade and the repeated stimuli might result in a false recovery state. The purpose of this study was to determine the best interval time of tetanic stimulation for evaluation of the correct PTC. Sixty adult patients undergoing stomach operations were randomly allocated to three groups according to the interval of tetanic stimulation ; group 1 (6 min. n=20), group 2 (8 min. n=20) and group 3 (10 min. n=20). In all cases, Anesthesia was maintained with 50% nitrous oxide, 50% oxygen and 1-2% enflurane following induction of anesthesia with thiopental sodium 3-5 mg/kg. Neuromuscular block was achieved by intravenous pancuronium bromide 0.13 mg/kg before application of ulnar nerve stimuli using Myotest MKII. The adduction force of the resultant thumb twitch was measured by the acceleration of a small piezo-electric ceramic wafer with electrodes of Mini-accelograph and recorded by Datascope 2200 I After 1 Hz single twitch stimulation, a tetanic stimulus(50 Hz) was applied for 5 sec. Three seconds later, the single twitch stimulation was again applied for 1 min. followed by 1 min. of TOF stimulation. This pattem of tetanic stimulation was continued by the interval of 6, 8 and 10 min. The results were as follows: 1. The continuance (which was the percentage when PTC was continuously increased, not intermittently reduced) was 73.7% in group 1 and 2, but 100% in group 3 and there were statistically significance. 2. In the regression analysis between FI'C and time from PTC1, we yielded the following equations ; Y=10+3.5X (r(2)=0.71) for group 1, Y=8.6+4.1X (r(2)=0.78) for group 2 and Y=9.8+5.7X (r(2)=0.69) for group 3. The slope and intercept of the line of group 3 showed significantly different to that of group 1 and 2 (p<0.001). The more frequent tetanic stimulation reduced the time to arrive the same PTC. 3. The time from PTCl to TOFl was 51.6+/-3.9 min. in group 1, 65+/-5 min. in group 2 and 69+/-4.3 min. in group 3. There were no statistically significance, but they had trend to reduce by more frequent tetanic stimulation. 4. PTC was 12.9+/-0.9 in group 1, 14.9+/-1.5 in group 2 and 13.2+/-0.8 in group 3 when TOF1 was appeared, and 38.3+/-2.3 in group 1, 33.3+/-2.3 in group 2 and 32.4+/-2.6 in group 3 when the second response to TOF stimulation(TOF2) was recorded(meanSEM). There were no statistically significance. With the above results the authors concluded that 10 min. will be the optimal interval of the tetanic stimulation for the correct PTC, and recognized that the interval of tetanic stimulation was not related to the time from PTC1 or PTC at TOF twitches.
Changes in Arterial Blood Gases during Laparoscopic Cholecystectomy under the General Anesthesia.
Chang Young Jeong, Myung Ha Yoon, Jae Hyeong Na
Korean J Anesthesiol. 1995;28(5):682-687.
Changes in arterial blood gases and arterial pressure during laparoscopic cholecystectomy under the general anesthesia (enflurane in N2O/O2 50%) were investigated in 30 patients, who were divided into two groups according to control of minute ventilation. During surgery, minute ventilation was set 100 ml/kg in group I and 150 ml/kg in group II, and intraabdominal pressure was maintained at 15mmHg by CO2 insufflation, in both groups. Variables were measured before CO2 gas insufflation, 15 and 30 minutes after insufflation, just after exsufflation, 15 and 30 minutes after exsufflation and in recovery room. 1. PaCO2 was increased significantly during CO2 gas insufflation and just after exsufflation in both group, and degree of increase (PaCO2) was significantly greater in group I compared to group II. 2. Changes of PaO2 were not statistically significant in comparison to control value and between two groups during CO2 gas insufflation and exsufflation. 3. Blood pH in both groups were lowered significantly compared to control value during CO2 gas insufflation and exsufflation, and group II (increased minute ventilation group), represents lower risk of acidosis compared to group I. 4. Mean arterial pressure and airway pressure were significantly increased compared to control value during CO2 gas insufflation, but there was no significant difference between two groups. These results suggest that minute ventilation during laparoscopic cholecystectomy should be increased up to maintaining normal PaCO2 for prevention of hemodynamic and blood gas changes due to CO2 retention.
The Effects of Epidural Clonidine Added to Bupivacaine , Fentanyl and Epinephrine after Total Abdominal Hysterectomy.
Sung Soo Choi, Geum Young So, Chong Dal Chung
Korean J Anesthesiol. 1995;28(5):688-693.
Epidurally administered clonidine, a selective alpha2-adrenergic agonist, has been reported to produce postoperative analgesia. The aim of this study was to see if the addition of a small dose of clonidine to a mixture of bupivacaine, fentanyl and epinephrine prolonged the duration of analgesia and reduce the number of injections or the total bupivacaine requirement and the incidence of side effects. Forty patients presenting for TAH in ASA physical status 1 or 2, were randomly divided into two groups group 1 was given a 10 ml epidural solution of bupivacaine 12.5 mg combined with fentanyl 50 pg and epinephrine 50ug ; group 2 was given the same solution with clonidine 75 ug. Changes in the systolic and diastolic blood pressure and the pulse rate were recorded at 5, 10, 20, 30, 45, 60, 75, 90, 105 and 120 minutes after drug administration, and the analgesic effects were assessed by measuring pain score (Prince Henry Score), analgesic duration, total bupivacaine requirement for 24 hours and side effect. The results were as follows; 1) Heart rate changed little in group 1 and decreased significantly in group 2. 2) Systolic and diastolic blood pressure decreased significantly in all groups (earlier in group 2 than in group 1). 3) The mean duration of analgesia was significantly prolonged in group 2, compared with group 1 (437 min in group 2; 229 min in group 1). For 24 hours after the first injection, numbers of injections (6 in group 1; 3.15 in group 2) and total bupivacaine requirements (75.0 mg in group 1 ; 39.1 mg in group 2) were significantly reduced. 5) The side effects including hypotension, nausea and vomiting, pruritus, and respiratory depression were not significantly different from each other. These results show that epidurally administered clonidine helps to prolong analgesic duration, and decreased need for supplemental bupivacaine, after lower abdominal surgery.
Epidural Morphine Spray for Pain Relief after Spine Surgery.
Jin Kook Yun, Jong Il Kim, Jong Seock Ban, Byung Woo Min
Korean J Anesthesiol. 1995;28(5):694-698.
Adequate postoperative pain control is in highlight because it has been known that uncontrolled pain has adverse effects on postoperative cardiopulmonary, immunologic functions and in turn, possibly prolongs patient's recovery. One hundred and two patients who underwent spine surgery including laminectomy, fusion and fixation were given 10mg of morphine into operative field (exposed epidural area) just prior to wound closure for relief of postoperative pain. These patients were compaired with 51 patients who did not received epidural morphine. The median of the numerical rating scale of epidural morphine spray group (Group A) at 4, 12, 24 hours after operation revealed 2, 3, 5 respectively and no epidural morhine group (Grade B) revealed 4, 5 and 5. In conclusion, postoperative pain relief of group A is superior to that of group B.
A Study on Autotranfusion in Spinal Surgery: Comparison between autotransfusion and homologous transfusion.
Sang Hwan Do, Young Jin Lim, Chong Soo Kim, Ji Ho Lee, Hong Ko, Byung Moon Ham
Korean J Anesthesiol. 1995;28(5):699-707.
It is well documented that autotransfusion can reduce or eliminate the use of homologous blood. And recently many studies have shown that autotransfusion influences postoperative course so that patients transfused with autologous blood show less tumor recurrence rate or less wound infection rate than those transfused with homologous blood. So we conducted a study on autotransfusion compared with homologous transfusion in patients undergoing posterior spinal fusion procedures. Autotransfusion group consisted of predonation and hemodilution group. In predonation group (n=20), autotransfusion was performed by autologous preoperative donation, intraoperative salvage using Cell saver and postoperative salvage using Orth-evac drainage/ reinfusion device. In hemodilution group (n=20), autotransfusion was performed by acute normo-volemic hemodilution and intraand postoperative autotransfusion methods same as predonation group. Above autotransfusion group was compared with homologous transfusion group (n=20) on perioperative CBC (complete blood count) changes, amount and duration of postoperative drainage, transfusion side effects and complications associated with operation. Results are as follows, 1) 90% of patients in autotransfusion group could complete transfusion therapy without the use of homologous blood. 2) Total amounts of transfused blood were 1,733+/-567 ml (5.4+1.8 units) in predonation group, 1,539+/-712 ml (4.8+2.2 units) in hemodilution group and 4.7+/-1.3 units in homologous transfusion group. There is no statistically significant difference between autotransfusion and homologous transfusion group. 3) In predonation group, hemoglobin and hematocrit levels were significantly lower than those of homologous transfusion group preoperatively and at PAR (postanesthetic recovery), 2nd day and 7th day postoperatively. But at 14th day, the levels were recovered as high as those in homologous transfusion group. 4) In autotransfusion group, total amount and the duration of postoperative drainage were significantly less and shorter respectively than those of homologous transfusion group. 5) In homologous transfusion group, 60% of patients experienced one or more than one of transfusion side effects and one patient received emergency operation of hematoma evacuation immediate postoperatively. In autotransfusion group, 47.5% of patients showed fever above 38degree Centigrade, and all of which were associated with the use of postoperative autotransfusion but other complications associated with transfusion or operation could not be found. In conclusion, we think autotransfusion not only can reduce or eliminate the use of homologous blood but also seems to have beneficial influences on postoperative recovery.
Effect of Clonidine for Suppression of Shivering after General Anesthesia.
Kyung Hye Moon, Myung Ae Lee
Korean J Anesthesiol. 1995;28(5):708-712.
We have studied the efficacy of intravenous clonidine to suppress postoperative shivering. Forty healthy patients who received general anesthesia and required treatment for shivering after operation were allocated randomly to two groups. Group 1 received normal saline 5 ml. Group 2 received 75 mcg intravenous clonidine. 2 minutes, 5 minutes and 10 minutes after treatment, the efficacy of treatment was recorded. Five minutes after treatment, 75 mcg clonidine obliterated shivering in 80% of patients. In contrast, none of the patients treated with normal saline had improved. Mean arterial pressure and heart rate were decreased significantly in patients given 75 mcg intravenous clonindine. But, none of them had required treatment for hypotension or bradycardia. We might say that 75 mcg intravenous clonidine is effective to suppress postoperative shivering without significant side effects.
Case Reports
Subcutaneous Emphysema following Laparoscopic Cholecystectomy.
Jong Soo Yoon, Soon Im Kim, Kyung Ho Hwang, Sun Chong Kim, Wook Park, Sung Yell Kim
Korean J Anesthesiol. 1995;28(5):713-715.
Subcutaneous emphysema is one of the complications of the pneumoperitoneum necessary to perform laparoscopy. We experienced a case of extensive subcutaneous emphysema which was manifested by severe hypercarbia with respiratory acidosis and tachycardia during laparoscopic cholecystectomy in 65 years old female patient. Hypercarbia was reversed rapidly by hyperventilation and subcutaneous emphysema was resolved spontaneously on postoperative 3rd day almostly. The possible cause of subcutaneous emphysema in this case is dissection of the insufflated carbon dioxide from the peritoneal cavity via a trocar site to a tract along subcutaneous tissue planes. Immediate recognition, evaluation, and treatment is necessary since this can be a life threatening complication. And tension peu-mothorax should be ruled out. It is safe to monitor end tidal carbon dioxide tension or arterial carbon dioxide tension during the laparoscopic cholecystectomy.
Two cases of congenital tracheal stenosis noteced before and after open heart surgery.
Sang Don Yi, Sung O Kim, Chong Sung Kim, Seong Deok Kim
Korean J Anesthesiol. 1995;28(5):716-721.
Long, severe, and fixed congenital tracheal stenosis is a life-threatening anornaly and not relieved by endotracheal or tracheostomy intubation. The rarity of congenital tracheal stenosis has not allowed sufficient experience for the development of standard treatment methods, therefore, congenital tracheal stenosis still carries significant morbidity, with a mortality rate as high as 70%. We have followed up two patients managed by different methods, but O(2)-isoflurane-Fentanyl-vecuronium was used for induction and maintenace. We experienced one case of tracheoplasty with pericardial patch for extensive tracheal stenosis under extracorporeal circulation, and one case of slide tracheoplasty for funnel-shaped tracheal stenosis. The first case was noticed incidentally during anesthetic induction and the vocal cord was visible but 2.5 mm sized tube could not be advanced,so we used the guide wire which is used for central line, then we could intubate with some resistance. Tracheostomy was not allowed due to diffuse tracheal stenosis reaching from cricoid cartilage to carina. During the extra corporial circulation, the guide wire was inserted from operation field, and 3.5 mm sized tube was introduced via guide wire by anesthesiologist. After operation the grannulation tissue that obstructing airway, was noticed by bronchoscopy, and was removed, then he was weaned from ventilator successfully. The second case was discovered due to diffcult weaning from ventilator after open heart surgery. the bronchogrm showed right tracheal bronchus and diffuse tracheal stenosis from T2 to carina. He was ventilated initially with 4.0 mm sized endotracheal tube, and ventilated intermittently with other 2.5 mm sized endotracheal tube from operation field during tracheal anastomosis. After operation, he died with increased airway pressure and airway bleeding.
Acute Attack of Asthma and Pulmonary Collapse Induced by Tracheal Intubation.
Sung Won Kim, Jae Gon Kim, Joong Suk Lee, Byung Yon Kwon
Korean J Anesthesiol. 1995;28(5):722-727.
Identification of the presence of chronic obstructive pulmonary disease in the elderly patient who was scheduled for surgery is vitally important. If appropriate therapeutic and preventive measures should not be instituted, tracheal intubation of the patient should be associated with a number of complications. We experienced a case of acute attack of asthma and pulmonary collapse during endotracheal intubation. A 54-year-old male who was scheduled for an emergency of primary corneo-scleral suture have had history of bronchial asthma. On the preoperative physical examination, there was no specific finding except expiratory wheezing. After endotracheal intubation with the aid of ketamine 2 mg/kg, pancuronium bromide 0.1 mg/kg and lidocaine 2 mg/kg, iv, acute asthmatic attack was appeared. Breathing sounds on the both lung fields can not be audible during manual ventilation and SpO(2) was dropped to 70% at F(1)O(2) 1.0. To relieve asthmatic attack, epinephrine(1: 1.000) 0.5 ml, sc, aminophylline 4 mg/kg, iv and methyprednisolone 1 mg/kg, iv were injected. Erosion of tracheal mucosa, blood clots and mucous plugs were found by the fibroptic bronchoscopy. After removal of blood clots and mucus, lung compliance and SpO2 were improved. The patient was discharged 7 days later without any complications or sequelae.
A Case of high-Frequency Oscillatory Ventilation.
Gi Sun Hwang, Bu Jin Jung, Jong Do Park, Jong Sung Kim, Sung Duk Kim
Korean J Anesthesiol. 1995;28(5):728-733.
Neonates with severe respiratory distress syndrome who require high levels of assisted ventilation have a high mortality and morbidity rate. Morbidity is mainly composed of bronchopulmonary dysplasia which is a result of air leak syndrome(ALS), oxygen toxicity. Even with unsolved controversy, there is a possibility that high-frequency oscillatory ventilation would decrease the development or progression of ALS in infants with severe respiratory distress syndrome. ALS is defined as pulmonary interstitial emphysema or gross air leak such as pneumothorax. We experienced HFOV to be effective in the treatment of newborn infant with pneumothorax.
Difficult Intubation in Post-Orthognathic Surgical Patient.
Jun Rae Lee, He Sun Song
Korean J Anesthesiol. 1995;28(5):734-736.
This 17 year-old male patient had an experience of a difficult intubation problem on miniplate removal operation after orthognathic surgery, but he didn't have the same problem on a previous orthognathic surgery 1 year before. He suffers from mental retardation and speaking disability due to congenital brain damage. I think difficult exposure of the larynx was caused by the imbalance of neck muscle force and jaw instability, as result from surgery. The preoperative airway evaluation is very important because findings may dictate choice of intubation technique. A flexible fiberoptic laryngoscope may be the most useful aid to awake intubation in the patient with a known difficult airway.


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
101-3503, Lotte Castle President, 109 Mapo-daero, Mapo-gu, Seoul 04146, Korea
Tel: +82-2-792-5128    Fax: +82-2-792-4089    E-mail: journal@anesthesia.or.kr                
Business Name: Korean Society of Anesthesiologists
Business Registration: 106-82-07194
Representative: Young-Tae Jeon

Copyright © 2026 by Korean Society of Anesthesiologists.

Developed in M2PI

Close layer
prev next