Korean J Anesthesiol Search

CLOSE


Korean Journal of Anesthesiology 2006;51(3):375-378.
DOI: https://doi.org/10.4097/kjae.2006.51.3.375   
Airway Obstruction Resulting from Arthroscopic Shoulder Surgery under General Anesthesia: A case report.
Ji Hyun Moon, Heeseung Lee, Jong In Han, Guie Yong Lee, Sinyoung Kang
Department of Anesthesiology and Pain Medicine, College of Medicine, Ewha Womans University, Seoul, Korea. leehee@ewha.ac.kr
Abstract
The use of a shoulder arthroscopic procedure provides advantages in the diagnosis and treatment of shoulder injuries. However, this technique is not free from complications. We encountered a patient who presented with an airway obstruction caused by the accumulation of extraarticular arthroscopy fluid after arthroscopic shoulder surgery under general anesthesia.
Key Words: airway obstruction; arthroscopy; general anesthesia; shoulder